UNICACCESS UGP-CTR-X Pule Fa'asologa 1/2/4 Faitau

Fa'atonuga o le Fa'aaogaina o Mea
- Mount the device on a DIN rail using the provided mounting hardware.
- Use 4 twisted pairs of F/FTP/Cat6 network cable for wiring.
- Connect the power supply to the designated terminals following the color codes and terminal block configurations.
- Configure the inputs for push buttons, glass breaks, or door contacts as required.
- Configure the controller settings, including IP address and access rights management, through the interface.
- To exit construction mode on the controllers, press the RST button located next to the red terminals once.
Fa'amatalaga Lautele
Vaaia

Pulea Faitotoa
| Le aufaitau | 1 | 2 | 4 |
| Fa'ailoga | 10000 | ||
| Central Unit/Reader Protocol | OSDP V1/TTL/SSCP V2 | ||
| Central Unit/Hub Protocol | ONVIF A & C |
Paoa sapalai
- Input power 12V (DC) 1,5A or 48V (DC) 1,5A (with POE module)
- Relay 1 2 4
- Relay information NO/NC 48V / 2A max
- LED output 2 4 8
- LED output information LEDs 24V / 100mA max
- Logical inputs 3 6 12
- Logical input voltages 0- 24V max
- Power supply output 1 2 4
- Power supply output information 12V / 250mA
I/O Fa'aoga
Le aufaitau
- 1 configurable 2 configurable 4 configurable
- reader input: reader inputs: reader inputs:
- TTL (Wiegand) or TTL (Wiegand) or TTL (Wiegand) or
- RS485 (OSPD/SSCP) RS485 (OSPD/SSCP) RS485 (OSPD/SSCP)
Manaoga uaea
- Network cable/controller 4 twisted pairs F/FTP/Cat6
- Controller/reader cable 2 shielded twisted pairs Type LIYCY-P 2x2x0.75 mm²
- Maximum length WIEGAND – 100 m
- controller/reader SSCP / OSDP – 750 m
O isi fa'amatalaga
- Connectors: Color-coded double terminal block and detachable (up to 1.5mm²)
- Operating and storing Ethernet port 10/100 Mbps
- conditions From 0°C to 50°C
- Certifications EMC / Electrical Safety / FCC / UL
- Dimensions H x W x L 60 x 95 x 160
- mamafa 249g
- Mounting DIN rail mounting
- Gagana: Farani, Igilisi, Sipaniolo
- Warranty 2 tausaga
Fa'apipi'i
Fa'amauina: DIN rail faʻapipiʻiina
Uaea
| Ituaiga | Controller-side terminal block | RS485 reader-side terminal block | TTL reader-side terminal block | Input-side terminal block | Locking-side terminal block |
| Malosiaga (12V DC) | +12V | / | / | / | / |
| GND | / | / | / | / | |
| GND | / | / | / | / | |
| Puipuiga
sili ona malosi* |
Puipuiga oe lava | / | / | / | / |
| Malosiaga | / | / | / | / | |
| Ulufale mai
(push button, glass break, door contact) |
I LE A | / | / | NC po'o LE LEAI | / |
| I LE B | / | / | NC po'o LE LEAI | / | |
| I LE C | / | / | NC po'o LE LEAI | / | |
| GND | / | / | COM | / | |
|
Tagata faitau (faitau kata, keypad, ma isi) |
+12V | +12V | +12V | / | / |
| GND | - poʻo le GND | - poʻo le GND | / | / | |
| D0/L+ | L+ | D0 | / | / | |
| D1/L- | L- | D1 | / | / | |
| LEDG | / | LEDG | / | / | |
| LEDR | / | LEDR | / | / | |
|
Relay (locking) |
NC | / | / | / | NC |
| COM | / | / | / | COM | |
| COM | / | / | / | COM | |
| LEAI | / | / | / | LEAI |
- Only if the controller is in a power supply enclosure
Fa'asoa
- The controller’s configuration, including IP address settings and access rights management, is performed through its interface.
Exit construction mode
- To exit construction mode on the controllers, press the RST button located next to the red terminals once.
So'oga fa'atonu
- Tatala a web browser (Chrome, Mozilla, Edge, etc.).
- Enter the controller’s IP address in the search bar (192.168.1.150 by default).
- Alu i totonu:
- Username: admin
- Password: controller’s serial number (located on the back of the product or in the power supply enclosure).
Reset the controller IP
To reset the IP address, press the RST button next to the red terminal block for 5 seconds until the orange LED starts flashing. (Default IP address: 192.168.1.150)
FAʻAMATALAGA FCC
O lenei masini e tausisia le vaega 15 o Tulafono FCC. O le fa'agaioiga e fa'atatau i tulaga nei e lua:
- O lenei masini e le mafai ona fa'alavelave fa'alavelave, ma
- E tatau i lenei masini ona talia so'o se fa'alavelave e maua, e aofia ai fa'alavelave e ono fa'atupu ai le le mana'omia.
FAAMANATU: E le nafa le tagata ua fa'atagaina mo so'o se suiga po'o suiga e le'i fa'amaonia manino e le itu e nafa ma le usita'ia. O ia suiga e mafai ona fa'aleaogaina ai le pule a le tagata fa'aoga e fa'agaioi ai masini.
FAAMANATU: O nei meafaigaluega ua uma ona faʻataʻitaʻiina ma maua ai le tausisia o tapulaʻa mo se Vasega A masini numera, e tusa ai ma le vaega 15 o Tulafono FCC.
O tapula'a nei ua mamanuina ina ia maua ai se puipuiga talafeagai mai fa'alavelave fa'alavelave pe a fa'agaoioia masini i totonu o se siosiomaga fa'apisinisi. O mea faigaluega nei e gaosia, fa'aoga, ma mafai ona fa'aolaina le malosi ole alaleo ma, a le fa'apipi'iina ma fa'aoga i lalo ole tusi lesona, e ono fa'alavelave fa'alavelave i feso'ota'iga leitio. O le fa'aogaina o nei meafaigaluega i totonu o se nofoaga e nofo ai e ono mafua ai le fa'alavelave fa'aleagaina, i le tulaga lea o le a mana'omia ai le tagata fa'aoga e fa'asa'o le fa'alavelave i lana lava tupe fa'aalu.
The European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE) requires that used electronic devices should not be disposed of in the normal flow of electronic waste.
- Used devices must be collected separately to optimize recovery rates and recycling of the materials they contain, and reduce the impact on human health and the environment.
- The crossed-out trash bin symbol is placed on all products to remind users of the separate collection obligations.
- Consumers must contact local authorities or their retailer regarding the procedure for the removal of their device.
In accordance with European legislation, the level of compliance with Directive 2014/30/EU, the EMC Directive, our controllers comply with the standards: EN 50130-4 for immunity and EN 55032 for emissions. They also comply with the essential requirements of the POC Directive 2013/35/EU and meet the EN 62311: 2008 standard, according to Recommendation 1999/519/EC. A copy of our declaration is available upon request at: qualite@unicacces-groupe.com
Our products must be installed by qualified professionals. In the event of improper installation and/or usage that does not follow the recommendations outlined above (non-exhaustive), UNICACCES-GROUPE cannot be held responsible.
FAQ
- E toafia le au faitau o loʻo lagolagoina e le masini?
- E lagolagoina e le masini faʻasalalauga faʻatasi ma le 1, 2, poʻo le 4 faitau.
- O a avanoa avanoa avanoa mo feso'ota'iga tagata faitau?
- The device supports TTL (Wiegand) or RS485 (OSDP/SSCP) interfaces for reader connections.
- O a mea e maua ai le eletise mo le masini?
- The device can be powered by either 12V (DC) 1.5A or 48V (DC) 1.5A with a POE module.
Pepa / Punaoa
![]() |
UNICACCESS UGP-CTR-X Pule Fa'asologa 1/2/4 Faitau [pdf] Tusi Lesona a le Pule UGPCTR, 2BO23UGPCTR, UGP-CTR-X Pule Fa'asologa 1 2 4 Tusi Faitau, UGP-CTR-X Fa'asologa, Pule 1 2 4 Tusi Faitau, 1 2 4 Tusi Faitau, Faitautusi |