EPH PULE TR1V2-TR2V2 RF Suiga Autu

Fa'amatalaga
- Paoa sapalai: 200 – 240VAC 50-60Hz
- Fa'ailoga fa'afeso'ota'i: 230 Vac 10(3)A
- O le vevela o le siosiomaga: 0…45˚C
- Gaioiga otometi: Type 1. C.
- Vasega meafaigaluega: Vasega II meafaigaluega

- Tulaga filogia: Tulaga filogia 2
- Fa'ailoga IP: IP20
- Faatulagaina Impulse Voltage: Tete'e i voltage si'isi'i 2500V pei ole EN 60730
Fa'afefea lau TR1 TR2V2 galue
- Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
- The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
- When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
- It is possible to send a wireless signal in one direction or both.
- When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
- When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
- Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
- It is possible to have more than one set of TR1, TR2V, 2and, where required.
- Please see pages 9-13 for wiring examples
Ata uaea totonu mo TR1TR2V2
FAATUATUA: Installation should only be carried out by a qualified person and by wiring regulations.
Switching Options
Suiga Autu
- Link L to 3
Maualalo Voltagu Suia
- Remove the external controls link from the boiler PCB.
- Connect 2 and 3 to these terminals.
Fa'amauina & Fa'apipi'i
- The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
- Single-gang recessed back box.
- Pusa fa'apipi'i luga
- Directly mounted on a wall.
- Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
- Screw the backplate to the wall with the screws provided.
- Uea le pito i tua e pei o le ata uaea.
- Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m



Faʻamatalaga / faʻamatalaga LED

Tusi Lesona Press to activate or deactivate the Live out terminal.
Feso'ota'i Hold for 3 seconds to initialise the pairing process. The RF light will flash.
Toe setiina Press to reset the T, R1, TR2V2.
Fa'aaliga: The connection procedure is not required as both TR1 & TR2V2 are pre-paired
Fa'amatalaga LED
| LED | Lanu | Fa'amatalaga |
| Ola i le LED | Lanu mumu | E leai se voltage on the Live terminal. |
| Lanu meamata | E iai voltage i luga o le Ola i totonu o le laina - O le taimi nei o le a lafo se faailo RF i le isi RF Mains Switch e faʻagaoioi ai le Live out terminal. | |
| RF LED | Lanu pa'epa'e | Uila paepae pa'epa'e o lo'o fa'ailoa mai ai o lo'o feso'ota'i le fa'avevela. |
| O le moli RF o le a faaluaina moli pe a motusia le vevela. Siaki le fa'aogaina o le thermostat. | ||
| Fa'aaliga: O le moli RF o le a emo fa'afuase'i pe a lafo e le faiga ma maua se fa'ailoga mo feso'ota'iga. | ||
| Fa'aaliga: The RF light will blink once every second when in RF pairing by holding Connect. Press the Manual to exit from this state. | ||
| Ola i fafo LED | Lanu mumu | E leai se fa'ailoga fa'aagaga RF na maua mai le isi RF Mains Switch. |
| Lanu meamata | RF activation signal has been received from the other RF Mains Switch. |
To connect the TRI TR2V2
Faamolemole matau: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.
On TR1V2:
- Taofi
for 3 seconds until the RF LED flashes white.
On TR2V2:
- Taofi
mo le 3 sekone. - The RF LED will begin to flash, and the Live out LED will appear solid green.
- When connected, all three LEDs will appear solid.
On TR1V2:
- Oomi le
to exit the pairing mode. - After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.
To disconnect the TRI TR2V2
- Taofi
for 3 seconds until the RF LED flashes white. - Taofi
for 10 seconds until the Live in LED appears solid red.
On TR2V2:
- Taofi
for 3 seconds until the RF LED flashes white. - Taofi
Connect for 10 seconds until the Live in & Live out LED appears solid red.
On TRIV2:
- Tusitala
e alu ese. - The TRI TR2V2 is now disconnected.
Maua uila Examples
Example One way RF Switch: Programmer to Boiler – Mains Switching
TR1V2
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.
Fa'atonuga Fa'apipi'i
- Mains Switching Boiler
- Maualalo-Voltage Switching Boiler
- I luga o le TR2V2
- On the boiler PCB
- I luga o le TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
Example 2 Two Two-way RF Switch:
- Programmer to Motorised Valve
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

Fa'atonuga Fa'apipi'i
1. Main Switching Boiler
2. Low-Voltage Switching Boiler
3. Valve afi
- On the TRIV2
- On the boiler PCB
- On the TRIV2
- I luga o le TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the motorised valve.
Example 3 One way RF Switch:
Pump Overrun – Mains Switching
TR 1 v2
- On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

Faʻapipiʻi Faʻamatalaga
- Pamu i luga
- the TR2V2
- Link L to 3 to power the Live out terminal to the pump
Example 4 Two Two-way RF Switch: Pump Overrun
- Polokalama i Boiler
- Boiler to Pump – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact closes, sending 230V to activate the pump.
TR2V2
- On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
Faʻapipiʻi Faʻamatalaga
- Mains Switching Boiler
- Maualalo-Voltage Switching Boiler
- pamu
- I luga o le TR2V2
- On the boiler PCB –
- I luga o le TR2V2
- On the TRIV2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the pump.
Example 5 Two Two-way RF Switch: Unvented Cylinder:
- Polokalama i le maualuga Limit Thermostat
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out the contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
Fa'atonuga Fa'apipi'i
- Mains Switching Boiler
- Maualalo-Voltage Switching Boiler
- Temostat Tapulaa Maualuga
- Valve afi
- On the TRIV2
- On the boiler PCB
- I luga o le TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the High Limit thermostat.
EPH Pulea IE
technical@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665
EPH Pulea Peretania
technical@ephcontrols.co.uk
www.ephcontrols.co.uk/
faafesootai matou
+44 1933 322 072
Harrow, HAI IBD
FAQs
Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.
Q: O le a le mamao maualuga i le va o TR1V2 ma TR2V2 mo fesoʻotaʻiga lelei?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.
Pepa / Punaoa
![]() |
EPH PULE TR1V2-TR2V2 RF Suiga Autu [pdf] Tusi Taiala TR1V2, TR2V2, TR1V2-TR2V2 RF Suiga Autu, TR1V2-TR2V2, Su'e Su'e RF, Su'e Su'e, Suiga |

