DAIKIN RXF09AXVJU + FTXF09AXVJU

Daikin 9,000 BTU 21 SEER2 Oterra Series Ductless Mini-Split Heat Pump Air Conditioner User Manual

Brand: DAIKIN | Model: RXF09AXVJU + FTXF09AXVJU

1. Oloa Ua Ovaview

The Daikin Oterra R32 Series 9,000 BTU 230V Mini-Split Heat Pump is designed for efficient climate control in spaces up to 400 sq. ft. It offers 9,000 BTUs of cooling power (Min 4,400 BTU - Max 11,200 BTU) and 10,000 BTUs of heating capacity (Min 4,400 BTU - Max 14,300 BTU). This unit achieves a high 21 SEER2 energy efficiency rating, 10.2 HSPF2, 12.5 EER2, and 4.06 COP, ensuring efficient year-round climate control through DC Inverter technology.

Vaega Autu:

  • Exceptional Efficiency: 21 SEER2, 10.2 HSPF2, 12.5 EER2, and 4.06 COP for energy-efficient operation.
  • All-Season Comfort: Cooling from 50°F to 118.4°F and heating from 5°F to 64.4°F. Extended cooling operation down to -4°F with facility settings and wind baffle (not included).
  • Fa'aleleia le Tumau: Anti-Corrosion Treatment on the heat exchanger, Quick Warming Function, Automatic Defrosting, and a drain pan.
  • Avatu Fa'apitoa: Powerful Operation, ECO+ mode for energy efficiency, Blue Fin Protection, and a Titanium Apatite Photocatalytic Air Purifying Filter for superior air quality.
  • Tausiga Fa'afaigofie: Designed for easier upkeep.

2. Fa'amatalaga Saogalemu

Please read this manual thoroughly before operating your new air conditioning unit. Make sure to save this manual for future reference.

  • Fa'atonuga fa'apitoa: Installation of this appliance should be performed by a qualified service person in accordance with all national wiring regulations. Incorrect installation can lead to fire, electric shock, injury, or other hazards.
  • Saogalemu Faaeletise: Ensure the unit is properly grounded. Do not operate with wet hands. Disconnect power before any maintenance or cleaning.
  • Taulimaina o le pusaaisa: This unit contains R32 refrigerant. Only qualified personnel should handle refrigerant. Improper handling can cause injury or damage.
  • Kiliaina: Maintain adequate clearance around both indoor and outdoor units for proper airflow and safe operation.
  • Tamaiti ma Fagafao: Taofi tamaiti ma fagafao mai le iunite a'o fa'agaioiina ma tausia.

3. Seti & Fa'apipi'i

3.1. O Mea e Aofia ai

The Daikin Oterra Mini-Split system comes with a comprehensive installation kit to ensure a smooth setup process. Please verify all components are present upon delivery.

  • Oterra 9,000 BTU Wall Mount Indoor Fan Coil (FTXF09AXVJU)
  • Smart DC Inverter Condenser (RXF09AXVJU) Pre-charged with R32 Refrigerant
  • Pulea Mamao
  • 15 Ft 1/4 x 3/8 - Maxwell Refrigerant Line with Interconnecting Cables Installation Kit
  • 1/2 Whip
  • 30A Disconnect
  • Maxwell Wall Mounting Bracket
Daikin Oterra Mini-Split system components including indoor unit, outdoor unit, remote, and installation kit.
Ata 1: Ua umaview of the Daikin Oterra Mini-Split system components. This image displays the indoor fan coil, outdoor condenser, remote control, pre-flared installation kit, 15ft communication cable, and outdoor unit wall bracket.
All-inclusive installation kit items for Maxwell Mini-Split.
Ata 2: Auiliili view of the Maxwell all-inclusive installation kit. Items include 15' Gas & Liquid Insulated Copper Lines, Stranded and Unshielded 16 Gauge 4 Lead Interconnecting Cable, Wall Filler Putty, Decorative Wall Cap, Wall Sleeve Cylinder, Outdoor Unit Wall Bracket, Non-Adhesive Decorative Wrapping Tape, and 6 Ft. Long Flexible Condensate Drain Hose.

3.2. Fa'atonuga Fa'apipi'i

While the Daikin Oterra system includes an installation kit, professional installation is highly recommended to ensure proper function, safety, and warranty validity. Incorrect installation can lead to refrigerant leaks, electrical issues, and reduced efficiency.

Manatu Autu Fa'apipi'i:

  • Tu'uina i totonu o le Iunite: Ensure adequate clearance from the ceiling (at least 6-8 inches) for optimal airflow and efficiency. The unit's internal sensor measures room temperature from its location.
  • Tu'uina o le Iunite i fafo: The Maxwell Wall Mounting Bracket is included for secure installation. Ensure the unit is level to facilitate proper drainage. Consider protecting exposed line sets and electrical connections from environmental factors.
  • Feso'ota'iga eletise: The system requires a 30A Disconnect. All electrical wiring should comply with local codes and be performed by a qualified electrician.
  • Laina Fa'aaisa: The 15 Ft 1/4 x 3/8 Maxwell Refrigerant Line is pre-flared. Proper connection and vacuuming of the lines are crucial to prevent leaks and ensure system performance.
  • Alavai: Ensure the drain line has a continuous downward slope to prevent water accumulation and potential leaks.
Vitio 1: A detailed guide on mini split installation. This video demonstrates the unpacking, preparation of tools, installation of indoor and outdoor units, and trial operation steps for a mini-split system.
Vitio 2: This video showcases the installation of a mini split line set cover with a flexible duct, providing visual guidance on how to neatly conceal the refrigerant lines and wiring.

4. Fa'atonuga o Galuega

The Daikin Oterra Mini-Split system is operated via the included wireless remote control. The remote allows you to adjust temperature settings, fan speeds, operating modes (Cool, Heat, Dry, Fan), and access special features.

Galuega Fa'atonu mamao:

  • ON/OFF: Fa'aola le iunite i luga pe tape.
  • VELA ▲/▼: Fetuuna'i le vevela e mana'omia.
  • TULAGA: Select operating mode (Cool, Heat, Dry, Fan).
  • FAN: Adjust fan speed (Auto, Low, Medium, High).
  • Taupega: Control the vertical airflow direction. Horizontal airflow adjustment is manual.
  • ECO+: Fa'agaoioi le faiga fa'asao malosi.
  • MALOSI: Provides rapid cooling or heating for a short period.
  • MOE: E fetu'una'i ai le vevela mo se moe lelei.
  • TAIMI: Set on/off timers for automated operation.

The remote control displays the set temperature, but it does not act as a room temperature sensor. The unit's internal sensor is located on the indoor fan coil.

5. Tausiga

Regular maintenance ensures optimal performance and longevity of your Daikin Oterra Mini-Split system. Always disconnect power before performing any maintenance.

  • Fa'amamaina o le Ea: The unit features a washable air filter. Clean the filter regularly (e.g., every 2 weeks or as needed) to maintain airflow and air quality.
  • Titanium Apatite Photocatalytic Air Purifying Filter: This filter helps improve air quality. Refer to the full user manual for specific cleaning or replacement instructions.
  • Iunite i fafo: Keep the outdoor condenser coil clean and free from obstructions (leaves, debris). Ensure the drain pan is clear for effective condensation drainage.
  • Su'ega fa'apolofesa: Schedule annual professional maintenance to ensure all components are functioning correctly and to check refrigerant levels.

6. Faʻafitauli

If your Daikin Oterra Mini-Split system is not operating as expected, refer to the following common troubleshooting steps. For complex issues, contact a qualified HVAC technician.

  • E le o ki le Iunite: Check the power supply, ensure the 30A Disconnect is engaged, and verify the remote control batteries.
  • Le lava le mālūlū/vevela: Ensure air filters are clean. Check for obstructions around indoor/outdoor units. Verify the correct operating mode and temperature setting. Low refrigerant levels due to leaks can also cause this issue, requiring professional service.
  • Water Leaking from Indoor Unit: Check if the drain line is clogged or improperly sloped. Ensure the unit is installed level.
  • Pio e le masani ai: Minor operational noises are normal. Excessive or unusual noises may indicate a problem with the fan, compressor, or other internal components.
  • Fa'ailoga sese: The unit features Self-Diagnostics with Digital Display. If an error code appears, consult the full user manual for specific meanings and solutions.

7. Fa'amatalaga

Detailed specifications for the Daikin 9,000 BTU 21 SEER2 Oterra Series Ductless Mini-Split Heat Pump Air Conditioner.

Daikin Oterra Mini-Split system specifications and dimensions.
Ata 3: This image provides a detailed overview of the Daikin Oterra Mini-Split system's specifications, including energy efficiency ratings, BTU capacities for cooling and heating, operational temperature ranges, power supply, refrigerant type, piping connections, pre-charged piping length, sound pressure levels, and AHRI #. It also shows the dimensions of both the indoor and outdoor units.
Fa'amatalagaFa'amatalaga
Igoa Fa'ailogaDAIKIN
Fa'amatalaga Fa'ata'ita'iRXF09AXVJU + FTXF09AXVJU
Fua o Mea30.31 x 9.18 x 11.33 inches (Indoor Unit) | 21.68 x 26.50 x 11.18 inches (Outdoor Unit)
Numera fa'atusa meaRXF09AXVJU + FTXF09AXVJU
LeleiHigh Efficiency (21 SEER2, 10.2 HSPF2, 12.5 EER2, 4.06 COP)
Malosiaga0.75 Tons (9,000 BTU Cooling)
Tulaga Pio30 Tesipela
Ituaiga Fa'apipi'iVaelua Faiga
Fa'apitoa Fa'apitoaAuto-Changeover, Anti-Corrosion Heat Exchanger Treatment, Auto-Restart after Power Failure, Eco+ Mode, Washable Air Filter, Automatic Defrosting, Program Dry Function, Auto-Fan Speed Control, Self-Diagnostics with Digital Display, Backlit Wireless Remote Controller
Voltage230 Volts
Uatage60 watts
Ituaiga MeaKopa, Palasitika
Fa'aaofia VaegaIndoor Fan Coil, Outdoor Condenser, R32 w/ Installation Kit, 1/2 Whip, 30A Disconnect, and Wall Bracket
Fuafuaga o le Folafola400 futu faatafafa
PuaisaR-32

8. Tuutuuga & Lagolago

The Daikin Oterra Mini-Split system comes with a 12-TAUSAGA FA'AVAE FA'AMANATU. Please retain your proof of purchase and installation records for warranty claims.

Lagolago tagata fa'atau:

For technical assistance, troubleshooting, or warranty claims, please contact Daikin customer support or your authorized dealer. Ensure you have your model number and purchase date available when contacting support.

Pepa Fa'atatau - RXF09AXVJU + FTXF09AXVJU

Preview Tusitaiala mo le Fa'apipi'iina o le Daikin Serie Split R32
O le tusi lesona atoatoa mo le fa'apipi'iina o masini ea malulu a le Daikin Serie Split R32, e aofia ai fa'ata'ita'iga RXJ20A5V1B9, RXJ25A5V1B9, ma le RXJ35A5V1B9. E tu'uina atu ai fa'atonuga auiliili i le saogalemu, sauniuniga o le nofoaga, fa'apipi'iina o le iunite, paipa fa'amālūlū, feso'ota'iga eletise, fa'atinoina, ma le tausiga. E aofia ai fa'amatalaga fa'apitoa ma ta'iala mo le fa'aleleia o fa'afitauli.
Preview Fa'asinomaga fa'amatalaga i totonu o le Daikin Série Split R32
Fa'atonuga fa'apitoa fa'atasi i le va'aiga o le Daikin Série Split R32. Obsahuje bezpečnostné pokyny, postupy inštalácie, technické údaje ma riešenie problémov pre profesionálnych inštalatérov.
Preview Daikin Série split R32 RXF Inštalačná Príručka
Komplexná referenčná príručka pre inštalatérov Daikin Série split R32 (modely RXF20F5V1B, RXF25F5V1B, RXF35F5V1B, RXF42F5V1B). Poskytuje podrobné pokyny pre bezpečnú a správnu inštaláciu klimatizačných jednotiek.
Preview Daikin R32 Split Series Ea Fa'apipi'i Tusi Taiala
O se taʻiala atoatoa mo le faʻapipiʻiina o iunite fafo o le Daikin R32 Split series (2MXM40A2V1B9, 2MXM50A2V1B8), e aofia ai le sauniuniga o le nofoaga, paipa, fesoʻotaʻiga eletise, faʻatumuina, faʻatinoina, ma auala e saogalemu ai.
Preview Daikin R32 Split Series Installer Reference Guide
Taʻiala atoatoa mo le faʻapipiʻiina o masini ea malulu a le Daikin R32 Split Series, e aofia ai taualumaga faʻapipiʻi, puipuiga mo le saogalemu, faʻamatalaga faʻapitoa, ma le faʻaleleia o auala e foia ai faʻafitauli.
Preview Daikin R32 Split Series Installation Manual
O se taʻiala atoatoa mo le faʻapipiʻiina o ea malulu o le Daikin R32 Split series, e aofia ai le saogalemu, faʻatulagaina o le iunite, paipa, fesoʻotaʻiga eletise, ma auala e faʻagaoioia ai. E aofia ai numera faʻataʻitaʻi 2MXM68A2V1B8, 3MXM40A2V1B8, 3MXM52A2V1B8, 3MXM68A2V1B8, 4MXM68A2V1B8, 4MXM80A2V1B8, 5MXM90A2V1B8.