1. Folasaga
This manual provides comprehensive instructions for the safe and effective installation, operation, and maintenance of the Eaton B-line Series B422-1 1/2AL Right Angle Beam Clamp. This aluminum clamp is designed for securing pipes or conduits to structural beams at a right angle, offering a robust connection with a specified load capacity.
Please read this manual thoroughly before installation and retain it for future reference. Adherence to these instructions will ensure proper function and safety.
2. Fa'amatalaga Saogalemu
LAPATAʻIGA: O le le mulimulitaʻia o nei faʻatonuga mo le saogalemu e ono iʻu ai i le faʻaleagaina o meatotino, manuʻaga tuga, poʻo le oti.
- Ia ofuina i taimi uma mea faigaluega talafeagai mo le puipuiga o le tagata lava ia (PPE), e aofia ai mata tioata ma totigilima, i le taimi e faʻapipiʻi ai.
- Ensure the structural beam and the pipe/conduit are capable of supporting the combined weight of the clamp, attached items, and any potential loads.
- Do not exceed the maximum rated load capacity of 500 lbs for this clamp.
- Verify that all bolts and nuts are securely tightened to the manufacturer's recommended torque specifications (if available, otherwise ensure firm tightness without over-tightening).
- Asiasi le clamp and surrounding structure regularly for signs of wear, corrosion, or damage. Replace damaged components immediately.
- Installation should be performed by qualified personnel familiar with local building codes and safety regulations.
3. Vaega o oloa
The Eaton B-line Series B422-1 1/2AL Right Angle Beam Clamp typically consists of the following components:
- Autu clamp body (aluminum)
- U-bolt or similar pipe-securing mechanism
- Mounting bolts and nuts (quantity as required for secure fastening)

Ata 1: Illustration of the Eaton B422-1 1/2AL Right Angle Beam Clamp in an installed configuration.
This illustration demonstrates the correct installation of the Eaton B422-1 1/2AL Right Angle Beam Clamp. It shows the clamp securing a cylindrical pipe to the flange of a structural beam using two bolts and nuts. The clamp body is positioned over the beam flange, and the pipe is cradled by the U-shaped portion of the clamp, secured by the bolts.
4. Seti ma Fa'apipi'i
- Faailoa nofoaga e fa'atutu ai: Select a suitable structural beam that can safely support the intended load. Ensure the beam flange is compatible with the clamp's design.
- Tu'u le Clamp: Place the main body of the B422-1 1/2AL clamp over the edge of the structural beam's flange. The curved portion designed to hold the pipe should face downwards.
- Insert Pipe/Conduit: Carefully position the 1 1/2-inch pipe or conduit into the U-shaped cradle of the clamp.
- Fa'amau Fa'amau: Insert the provided bolts through the clamp body and the pipe-securing mechanism. Thread the nuts onto the bolts.
- Fa'amau So'oga: Using appropriate tools, gradually tighten the nuts evenly until the clamp firmly grips both the beam and the pipe. Avoid over-tightening, which can damage the clamp or the pipe. Ensure the clamp e mautu ma e le lūlūina.
- Su'ega Mulimuli: Visually inspect the installed clamp to confirm it is properly seated, all fasteners are tight, and the pipe is securely held.
5. Fa'atonuga o Galuega
The Eaton B422-1 1/2AL beam clamp is a static support device. Its "operation" primarily involves ensuring it remains securely installed and within its load limits.
- Gafatia o uta: Aua le tuuina atu le clamp to loads exceeding 500 lbs. This rating includes the weight of the pipe/conduit and any contents or attached equipment.
- Dynamic Loads: Lenei clamp is designed for static loads. Avoid applications involving significant vibration, shock, or dynamic forces unless specifically engineered for such conditions.
- Manatuga Siosiomaga: Ia mautinoa o le clamp is used in environments compatible with aluminum construction. Avoid exposure to corrosive agents that could compromise material integrity.
6. Tausiga
Regular maintenance ensures the longevity and safety of the beam clamp.
- Su'ega Fa'avaitaimi: Conduct visual inspections at least annually, or more frequently in harsh environments or high-stress applications. Check for:
- Fa'amau fa'amau.
- Signs of corrosion, cracks, or deformation on the clamp body or fasteners.
- Damage to the pipe or beam at the clampmea taua.
- Fa'amau Fa'amau: Re-tighten any loose bolts and nuts to ensure secure attachment.
- Fa'amamaina: Fa'amama le clamp as needed to remove dirt, dust, or debris that could obscure damage or contribute to corrosion.
- Suiga: If any part of the clamp shows significant wear, damage, or corrosion, replace the entire clamp assembly. Do not attempt to repair damaged clamps.
7. Faʻafitauli
This section addresses common issues that may arise with beam clamp fa'apipi'i.
- Clamp e tatala:
- Mafuaaga: Fasteners not tightened sufficiently or have loosened over time.
- Fofo: Re-tighten all bolts and nuts securely. If loosening persists, consider using thread-locking compound (if compatible with materials and environment) or consult a professional.
- Pipe/Conduit Slipping:
- Mafuaaga: Le lava clamping force, incorrect pipe size, or excessive load.
- Fofo: Ensure fasteners are tight. Verify the pipe diameter is 1 1/2-inch for optimal fit. Reduce the load if it exceeds the clamp's capacity.
- Visible Damage to Clamp:
- Mafuaaga: Overloading, impact, or material fatigue.
- Fofo: Immediately remove the clamp from service and replace it with a new, undamaged unit. Do not use damaged clamps.
8. Fa'amatalaga
| Uiga | Fa'amatalaga |
|---|---|
| Tufuga | Eaton Electrical |
| Numera Fa'ata'ita'i | B422-1 1/2AL |
| Numera Vaega | B422-1 1/2AL |
| Mea | Alumini |
| Pipe/Conduit Size Compatibility | 1 1/2-inisi |
| Maualuluga Fa'atatauina Uta | 500 lbs |
| Mea Saogalēmū | 5 |
| Aofa'iga o Mea'ai | 1 |
9. Lagolago ma Fa'amatalaga Fa'afeso'ota'i
For technical assistance, product inquiries, or to report issues, please contact Eaton Electrical customer support. Refer to the official Eaton website for the most current contact details and additional product resources.
Eaton Electrical Official Webnofoaga: www.eaton.com
Please note that product specifications and information are subject to change without notice. Always refer to the latest documentation provided by the manufacturer.