ACiQ ACiQ-48-AC

Tusitaiala mo le Fa'aaogāina o le ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System

Model: ACiQ-48-AC / ACIQ-60-ACL / IKIC51

1. Folasaga

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

2. Fa'amatalaga Saogalemu

Fa'atonuga Saogalemu Taua:

3. Oloa Ua Ovaview ma Vaega

The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.

Vaega Autu:

Vaega e aofia ai:

The complete system includes the following components:

ACiQ 4 Ton Central Air Conditioner System components

Ata 3.1: Ua umaview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

ACiQ Split System Installation Kit components

Ata 3.2: Auiliili view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

ACiQ Air Conditioner Condenser Unit Features

Ata 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.

4. Seti ma Fa'apipi'i

Fa'atonu Fa'apolofesa Manaomia: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.

The installation process typically involves:

  1. Filifiliga nofoaga: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
  2. Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
  3. Refrigerant Line Connection: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
  4. Uea eletise: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
  5. Alavai Condensate: Installing proper drainage for the indoor evaporator coil.
  6. Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
  7. Fa'apipi'i Thermostat: Wiring and configuring the Smart WiFi Thermostat.
  8. Su'ega Fa'atonu: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.

Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.

5. Fa'atonuga o Galuega

Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.

Smart WiFi Thermostat Operation:

The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:

Smart WiFi Thermostat features and interface

Ata 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.

For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.

6. Tausiga

Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.

User Maintenance (Monthly/Quarterly):

Professional Maintenance (Annually):

It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:

7. Faʻafitauli

A'o le'i fa'afeso'ota'i se tekinisia tautua, toeview the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.

Fa'afitauliMafuaaga e ono tupuFofo
System Not Cooling
  • Ua sese le seti o le thermostat
  • Fa'amama ea palapala
  • Outdoor unit obstructed
  • Fa'afitauli sapalai eletise
  • Refrigerant leak (system alert)
  • Check thermostat settings (mode, temperature).
  • Faamama pe sui le faamama ea.
  • Clear debris from outdoor unit.
  • Check circuit breaker; ensure disconnect switch is ON.
  • Contact a qualified technician for inspection and repair.
Vaivai le Ea
  • Fa'amama ea palapala
  • Blocked return air vents
  • Fa'afitauli alavai
  • Faamama pe sui le faamama ea.
  • Ensure all return air vents are open and unobstructed.
  • Consult a technician to inspect ductwork.
Pio e le masani ai
  • Vaega matala
  • O lapisi i totonu o le ili
  • Fa'afitauli tau afi
  • Turn off unit and inspect for loose panels or debris.
  • If noise persists or is severe, contact a technician.
Water Leakage (Indoor Unit)
  • Clogged condensate drain line
  • Frozen evaporator coil
  • Clear the condensate drain line.
  • Turn off cooling and allow coil to defrost; check airflow and refrigerant levels. Contact technician if problem persists.

If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.

8. Fa'amatalaga

Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:

Fa'amatalagaTaua
Fa'ailogaACiQ
Numera Fa'ata'ita'iACiQ-48-AC / ACIQ-60-ACL / IKIC51
Malosiaga4 Tone (48,000 BTU/h)
Efficiency (SEER2)15.5 VAAI2
Ituaiga RefrigerantR410A
Voltage230 Volts
Uatage4000 watts
Tulaga Pio56 dB
Fua o Iunite i fafo (L x W x H)16.14" x 37.24" x 52.48"
Indoor Coil Dimensions (W x D x H)24.49" x 20.98" x 27.99" (622 x 533 x 711 mm)
Ituaiga Fa'apipi'iVaelua Faiga
Fa'ailoga Fa'ailogaFaiga Vaeluaina Tutotonu
Ituaiga FilterWashable, Reusable Mesh Filter
Fuafuaga o le FolafolaE tusa ma le 2400 Square Futu
Fa'apitoa Fa'apitoaIunite Inverter, Sensors Atamai, Gold Fin Coil, Ultra-Fiemu, Fa'atinoga Lelei mo le Tau Uma
Dimensions of ACiQ outdoor condenser and indoor evaporator coil

Ata 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Specifications for ACiQ evaporator coil

Ata 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

AHRI Rating Conditions and EnergyGuide label for ACiQ system

Ata 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.

9. Fa'amaonia ma Lagolago

Tulaga Fa'amaonia: The ACiQ system comes with a 7-tausaga vaega fa'amaonia ma a 12-tausaga compressor warranty. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.

Lagolago tagata fa'atau: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official website or the documentation included with your purchase. You can also visit the ACiQ Store on Amazon mo nisi faamatalaga.

Pepa Fa'atatau - ACiQ-48-AC

Preview ACiQ Central Inverter Systems Tusi Lesona Fa'apipi'i Vaega i fafo
Faʻatonuga faʻapipiʻi tusi mo ACiQ Central Inverter Systems iunite i fafo, e aofia ai le puipuiga o le saogalemu, paipa pusaaisa, faʻapipiʻi iunite i fafo, uaea, faʻamatalaga o le eletise, faʻafefe o le ea, ma faiga faʻataʻitaʻiga. E aofia ai faʻamatalaga faʻataʻitaʻiga ma faʻamatalaga taua mo le seti saʻo.
Preview Tusitaiala mo le Fa'apipi'iina o Faiga Fa'apipi'i Tutotonu a le ACiQ
O le tusi taiala atoatoa mo le faʻapipiʻiina o le ACiQ Central Inverter Air Conditioning ma le Heat Pump Systems, faʻamatalaina auiliili ai puipuiga mo le saogalemu, paipa faʻamālūlū, faʻapipiʻiina o iunite i fafo, uaea, faʻamatalaga o le eletise, faʻaliliuina o le ea, ma faʻataʻitaʻiga o le faʻataʻitaʻiga.
Preview ACiQ Central Inverter Systems Tusi Lesona Fa'apipi'i Vaega i fafo
Faʻatonu tusi faʻapipiʻi mo ACiQ Central Inverter Systems iunite i fafo, e aofia ai puipuiga o le saogalemu, paipa pusaaisa, uaea, faʻapipiʻi iunite, ma suʻega faʻataʻitaʻiga mo faʻataʻitaʻiga e pei ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, ma isi.
Preview ACiQ R32 Unitary Air Handler & Heat Pump Condenser Technical Sales Guide
O lenei taʻiala faʻatauga faʻapitoa o loʻo tuʻuina atu ai faʻamatalaga auiliili, faʻamatalaga faʻatinoga, fua, ma faʻataʻitaʻiga faʻapipiʻi mo le ACiQ R32 Unitary Air Handler ma Heat Pump Condenser faasologa, e aofia ai faʻataʻitaʻiga ACiQ-24/36/48/60-AH32 ma ACiQ-24/36/48/60-HP32.
Preview ACiQ Ducted Air Handler Tusi Lesona Fa'apipi'i (12K-60K BTU/h)
O lenei tusi faʻapipiʻi mai le ACiQ o loʻo tuʻuina atu ai faʻamatalaga auiliili mo le saogalemu ma le saʻo o le faʻapipiʻiina o iunite Ducted Air Handler, faʻataʻitaʻiga 12K i le 60K BTU/h. O lo'o aofia ai ta'iala mo le saogalemu, tu'uina o iunite, paipa fa'aaisa, uaea eletise, fa'amatalaga, ma su'ega fa'atino ina ia mautinoa lelei le fa'atinoga ma le umi ole faiga.
Preview ACiQ Next Gen ducted Heat Pump System Ta'iala vave amata
Quick Start Guide for the ACiQ Next Gen Ducted Heat Pump System, covering wiring diagrams, thermostat connections, and DIP switch settings for various installation scenarios.