Model: PNOZ S3 24VDC (750103)
Brand: PILZ
This manual provides essential information for the safe and effective use of the PILZ PNOZ S3 safety relay. The PNOZsigma safety relay is designed for monitoring safety functions in industrial applications, ensuring reliable operation of emergency stop buttons, safety gates, and light curtains.
Please read this manual thoroughly before installation, operation, or maintenance to ensure proper functionality and to prevent potential hazards.
LAPATAIGA: This device must be installed and maintained by qualified personnel only. Failure to follow these instructions can result in serious injury or death.

Figure 1: PILZ PNOZ S3 Safety Relay
The PILZ PNOZ S3 is a compact safety relay designed for monitoring safety functions. Its narrow 17.5 mm width allows for space-saving installation in control cabinets.
Vaega Autu:
Fa'amatalaga ata: O se itu view of the PILZ PNOZ S3 safety relay, showcasing its distinctive yellow and black housing. The top section features two sets of terminals, labeled 'EX' and 'LX', indicating expansion and input connections. Below these, a row of terminals is visible, marked 'A1', '13', '23', 'S12', 'S22', and 'S34', which are typically used for power supply and safety inputs. The side panel of the unit clearly displays the product name 'PILZ PNOZ S3' and a vertical array of indicator lights. These lights are labeled 'Power', 'In1', 'In2', 'Out', 'Start', and 'Fault', providing visual feedback on the relay's operational status. At the bottom, another set of terminals is present, labeled 'S11', 'S21', 'Y32', 'A2', '14', and '24', which are typically for safety outputs and auxiliary connections. The overall design emphasizes a compact, industrial-grade construction with clear labeling for ease of installation and monitoring.
The PNOZ S3 is designed for DIN rail mounting. Ensure the mounting surface is stable and free from excessive vibration. Mount the device vertically to ensure proper heat dissipation.
Use appropriate wire gauges for all connections. The device features plug-in screw-type terminals for secure wiring. Refer to the terminal designations on the device for correct connections.
Ensure all connections are tight and secure to prevent intermittent operation or safety hazards.
After completing all wiring and verifying connections, apply power to the device. The "Power" indicator light should illuminate.
| Fa'ailoga | Tulaga | Fa'amatalaga |
|---|---|---|
| Malosiaga | lanu meamata (ON) | Ua ola le masini. |
| In1, In2 | lanu meamata (ON) | Safety inputs are closed (e.g., E-STOP released, safety gate closed). |
| I fafo | lanu meamata (ON) | Safety outputs are active (relay contacts closed). |
| Amata | lanu meamata (ON) | Start condition met (e.g., start button pressed, automatic start enabled). |
| Sese | Red (ON/Flashing) | Indicates an internal fault or wiring error. Refer to troubleshooting. |
Once all safety inputs are closed (In1, In2 lights are green), the device is ready to be started. Depending on the configuration:
To stop the safety function, activate a safety input (e.g., press E-STOP, open safety gate). The "Out" light will extinguish, and the safety outputs will de-energize.
The PILZ PNOZ S3 safety relay is designed for minimal maintenance. However, regular inspections are recommended to ensure continued safe operation.
All maintenance and testing should be performed by qualified personnel.
This section provides guidance for common issues. For complex problems, contact PILZ technical support.
| Fa'afitauli | Mafuaaga e ono tupu | Fofo |
|---|---|---|
| "Power" light is off. | Leai se eletise po'o le sa'o voltage. | Check 24 V DC power supply to terminals A1/A2. Verify voltage. |
| "In1" or "In2" light is off when inputs should be closed. | Open safety input circuit (e.g., E-STOP pressed, safety gate open, wiring error). | Check continuity of safety input devices and wiring to S12, S22, S34. Ensure all safety devices are in their safe (closed) state. |
| "Out" light does not illuminate after start attempt. | Safety inputs not closed, start condition not met, or internal fault. | Verify "In1" and "In2" lights are green. If manual start, ensure start button is pressed and "Start" light illuminates. Check "Fault" light. |
| "Fault" light is red. | Internal device fault, short circuit in input wiring, or incorrect wiring. | Disconnect power, re-check all wiring according to the manual. If fault persists, the device may be defective. |
| Parameter | Taua |
|---|---|
| Fa'ata'ita'iga | PNOZ S3 24VDC (750103) |
| Ulufale mai | 1/2-channel wiring with/without detection of shorts across contacts |
| Amata Filifiliga | Tusia/Autometi |
| Saogalemu Galuega | 2 N/O (Normally Open) |
| Galuega Faatino Ausilali | 1 SC (Signaling Contact) |
| Sapalai Voltage | 24 V DC |
| Lautele | 17.5 mm |
| Terminals | Plug-in screw type |
| Mata'ituina Galuega | E-STOP, faitotoʻa saogalemu, puipui moli |
| Mea mamafa | 0.01 aunese |
| Ituaiga Feso'ota'i | Sulu i totonu |
| Fa'afeso'ota'i Mea | Nikeli |
| Ituaiga Faafesootai | E masani ona tatala |
| Ituaiga Fa'amau | Fa'amau i le Mauga |
Specific warranty terms for the PILZ PNOZ S3 safety relay are provided by the manufacturer, PILZ. Please refer to the warranty documentation included with your purchase or visit the official PILZ website for detailed information regarding warranty coverage, duration, and conditions.
Taofi lau fa'amaoniga o le fa'atau mo so'o se tagi fa'amaonia.
For technical assistance, product inquiries, or support regarding the PILZ PNOZ S3 safety relay, please contact PILZ directly.
When contacting support, please have your product model (PNOZ S3 24VDC) and any relevant error messages or observations ready.
![]() |
Pilz PNOZ s3 Safety Relay Operating Manual Comprehensive operating manual for the Pilz PNOZ s3 safety relay, covering installation, operation, technical details, and safety features for industrial automation applications. |
![]() |
Pilz PNOZ s3 Safety Relay Operating Manual This operating manual provides comprehensive details on the Pilz PNOZ s3 safety relay, covering its functions, installation, wiring, operation, and technical specifications for industrial safety applications. |
![]() |
Pilz PNOZ s3 Saogalemu Relay: Fa'agaioiga Tusi Taiala ma Fa'amatalaga Fa'ainisinia Fa'atonuga fa'aoga tusi ma fa'amatalaga fa'apitoa mo le Pilz PNOZ s3 le saogalemu, ufiufi foliga, fa'apipi'i, uaea, fa'agaioiga, fa'afitauli, ma fa'amatalaga fa'apitoa. |
![]() |
PILZ PNOZ s3 Sicherheitsschaltgerät Technische Daten und Spezifikationen Detaillierte technische Daten für das PILZ PNOZ s3 Sicherheitsschaltgerät, einschließlich elektrischer, mechanischer und Umweltdaten, Sicherheitskennzahlen, Lebensdauerkurven und Zulassungen. |
![]() |
Pilz PNOZ X6 Saogalemu Relay Fa'agaoioiga Tusi Lesona Faʻatonuga faʻaoga tusi mo le Pilz PNOZ X6 saogalemu relay, e aofia ai ana galuega, faʻapipiʻi, uaea, faʻagaioiga, ma faʻamatalaga faʻapitoa. E aofia ai ta'iala saogalemu ma fa'amatalaga oka. |
![]() |
Pilz PNOZmulti 2 Kommunikationsschnittstellen Bedienungsanleitung Diese Bedienungsanleitung beschreibt die Kommunikationsmöglichkeiten und Schnittstellen für das konfigurierbare Kleinsteuerungssystem Pilz PNOZmulti 2, einschließlich Feldbus- und Ethernet-Kommunikation. |