Astralpool 57178

ASTRALPOOL Pamu Peristaltic 12L/H 1 pa (Fa'ata'ita'iga 57178) Tusita'iala

1. Folasaga

1.1 Oloa Ovaview

The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.

1.2 Fa'amatalaga Saogalemu

Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.

  • Aveese i taimi uma le eletise aʻo leʻi faia soʻo se faʻapipiʻi poʻo se tausiga.
  • Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
  • Fa'amaonia o le sapalai eletise voltage matches the pump's requirements (230 Volts AC).
  • Do not operate the pump with damaged cables or connections.
  • Wear appropriate personal protective equipment (PPE) when handling chemicals or performing maintenance.

2. Seti ma Fa'apipi'i

2.1 Fa'amauina o le pamu

Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.

2.2 So'oga Fa'aeletise

The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.

2.3 Fluid Connections

Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

Astralpool Peristaltic Pump 57178 showing the transparent cover, internal tubing, and connection ports.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.

3. Fa'atonuga o Galuega

3.1 Amata amata

  1. Ensure all fluid connections are secure and the pump is properly mounted.
  2. Verify that the fluid source is available and the discharge line is correctly routed.
  3. Plug the pump into the power supply.

3.2 Flow Regulation

The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).

4. Tausiga

4.1 Tausia Lautele

  • Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
  • Check all connections for leaks and tighten if required.
  • Keep the pump's exterior clean and free from dust and debris.

4.2 Fa'amamāina

To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.

5. Faʻafitauli

Fa'afitauliMafuaaga e ono tupuFofo
E le amata le pamuLeai se eletise
Ua leaga uaea eletise
Siaki le feso'ota'iga eletise ma le so'oga
Inspect and replace cable if damaged
Leai se vai tafeUa kink pe poloka le paipa
Ua poloka le faamama totonu
Potentiometer set to 0%
Inspect and clear tubing
Fa'amama pe sui le fa'amama totonu
Adjust potentiometer to desired flow rate
Inconsistent flowEa i le laina
Worn tubing
Fa'atoto le ea mai le faiga
Replace peristaltic tubing
Leakage at connectionsSo'oga matala
Damaged seals/tubing
Fa'amau so'otaga uma
Inspect and replace seals or tubing

6. Fa'amatalaga Fa'apitoa

Fa'amatalagaTaua
Fa'ailogaAstralpool
Numera Fa'ata'ita'i57178
Fua o Mea (L x W x H)23 x 11 x 13 cm
mamafa900 kalama
Voltage230 Volta (AC)
Fua o le tafeUp to 12 L/H (continuously adjustable)
Malosi maualuga1 pa
Avanoa Vaega Fa'apitoaLe maua fa'amatalaga

Pepa Fa'atatau - 57178

Preview AstralPool Halo Doser PH Dosing Module Installation Manual
Installation manual for the AstralPool Halo Doser PH Dosing Module, covering safety instructions, system overview, installation, control, maintenance, and troubleshooting.
Preview Astralpool Acqua Dos Manual Analog Dosing Pump Quick Start Guide
Concise guide to installing, connecting, and operating the Astralpool Acqua Dos Manual Analog dosing pump for pool chemical treatment. Includes technical specifications, materials, electrical and hydraulic connections, and control panel functions.
Preview AstralPool QB800 Robotic Pool Cleaner: Tusitaiala ma le Taiala mo le Tagata Faʻaoga
O lenei tusi lesona o loʻo tuʻuina atu ai faʻatonuga auiliili mo le faʻapipiʻiina, faʻaogaina, tausiga, ma le faʻaleleia atili o le faʻaaogaina o le AstralPool QB800 Robotic Pool Cleaner.
Preview ASTRALPOOL Ta'iala Tausia u'amea mo Vai Talosaga
Ta'iala taua mo le tausiaina o vaega u'amea u'amea ASTRALPOOL i si'osi'omaga vai. Aʻoaʻo faiga sili mo le faʻamamaina, puipuia o le faʻamaʻiina, ma faʻamautinoa le umi o le ola.
Preview AstralPool Classic Plus Multiport Valve: Fa'apipi'i, Tausiga, ma Taiala Fa'afitauli
Taiala auiliili mo le AstralPool Classic Plus multiport valve (faataitaiga 73950-1000). Ufiufi galuega valve, fa'apipi'i la'asaga i lea la'asaga, faiga fa'aleleia taua, lisi atoa o vaega, ma fa'afitauli fa'afitauli masani mo faiga faamama vaita'ele.
Preview AstralPool Halo Xpand Automation Expansion Module Installation Manual
This manual provides installation instructions for the AstralPool Halo Xpand Automation Expansion Module, detailing system overview, mounting, power connections, pairing, configuration, control methods, and troubleshooting.