COTEK SP-3000-112

Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter User Manual

Model: SP-3000-112

1. Folasaga

This manual provides essential information for the safe and efficient operation of your Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter. This device converts 12V DC power from batteries into 120V AC power, suitable for a wide range of electronic appliances. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Fa'amatalaga Saogalemu

Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death. Always exercise caution when working with electrical equipment.

Illustration of a battery with a recycling symbol
Always handle batteries with care and ensure proper disposal.
Hard hat, safety glasses, and gloves on a wooden surface
Wear appropriate personal protective equipment during installation and maintenance.

3. Oloa Ua Ovaview

3.1 Vaega Autu

3.2 Inverter Components

Cotek SP-3000-112 Pure Sine Wave Inverter, front-side view
Ata 1: Aotelega view of the Cotek SP-3000-112 Pure Sine Wave Inverter. This image shows the robust blue and grey casing, ventilation grilles, and the general form factor of the unit.
Rear panel of the Cotek SP-3000-112 Inverter showing AC outlet and controls
Ata 2: Rear panel of the inverter. Visible components include the hardwire AC output terminal, the main power switch (ON/OFF), LED indicators, DIP switches for settings, and an RJ45 port for remote control.
Front panel of the Cotek SP-3000-112 Inverter showing DC input terminals and cooling fan
Ata 3: Front panel of the inverter. This view highlights the heavy-duty DC input terminals (red for positive, black for negative), the chassis ground connection, and the cooling fan vents.
Close-up of the control panel on the Cotek SP-3000-112 Inverter
Ata 4: Auiliili view of the control panel. This section includes the LED indicators (Power, Fault, Overload), DIP switches for configuration, the RJ45 remote control port, and the green terminal for remote ON/OFF control.

4. Seti ma Fa'apipi'i

Proper installation is crucial for the safe and efficient operation of your inverter. Refer to local electrical codes and standards.

4.1 Tulaga

4.2 Uaea

All wiring must comply with applicable electrical codes and be performed by a qualified electrician.

  1. Fa'avae: Connect the inverter's chassis ground terminal to a reliable earth ground using appropriate gauge wire.
  2. DC Input Connection:
    • Ensure the battery bank voltage 12VDC.
    • Use appropriately sized cables for the DC input to minimize voltage drop and ensure safety. Refer to cable sizing charts based on current and distance.
    • Connect the positive (+) terminal of the battery bank to the red (+) terminal on the inverter.
    • Connect the negative (-) terminal of the battery bank to the black (-) terminal on the inverter.
    • Install a DC-rated fuse or circuit breaker between the battery bank and the inverter's positive terminal, as close to the battery as possible.
  3. Feso'ota'iga Fa'aulufalega AC:
    • Connect your AC loads to the hardwire AC output terminal block.
    • Ensure the total load does not exceed the inverter's continuous power rating (3000W).
  4. Pulea Mamao (Filifili): Connect the remote control unit to the RJ45 port or use the green terminal for external ON/OFF control if desired.

5. Fa'atonuga o Galuega

5.1 Fa'aola i luga/Pepe

  1. I le Malosiaga: Ensure all DC and AC connections are secure. Flip the main power switch on the inverter's rear panel to the 'ON' position. The Power LED indicator should illuminate.
  2. Tape le Malosi: Disconnect all AC loads from the inverter. Flip the main power switch to the 'OFF' position.

5.2 Fa'ailoga LED

The inverter features 3-color LED status indicators on the control panel (refer to Figure 4) to provide operational feedback:

5.3 Fa'asagaga Suiga DIP

The DIP switches on the control panel allow for customization of certain inverter parameters, such as output voltage, frequency, and power saving mode. Refer to the detailed specifications table (Figure 5) or the product datasheet for specific configurations. Always adjust DIP switches when the inverter is powered off.

6. Tausiga

Regular maintenance ensures the longevity and reliable operation of your inverter.

7. Faʻafitauli

O lenei vaega o loʻo tuʻuina atu ai fofo i faʻafitauli masani e te ono feagai. Afai e faʻaauau pea le faʻafitauli, faʻafesoʻotaʻi le tautua a tagata faʻatau.

Fa'afitauliMafuaaga e ono tupuFofo
E le kilia le Inverter.No DC input power; Loose battery connections; Blown DC fuse/breaker; Inverter switch OFF.Siaki maa voltage; Tighten connections; Replace fuse/reset breaker; Turn inverter switch ON.
Leai se gaosiga AC.Overload; Short circuit; Over-temperature shutdown; Low/High DC input voltage.Reduce AC load; Check for short circuits in wiring/appliances; Allow inverter to cool; Check battery voltage.
Yellow LED illuminated.Ma'a maualalo voltage warning; High temperature warning.Recharge batteries; Ensure adequate ventilation, reduce load.
Red LED illuminated / Inverter shut down.Overload; Short circuit; Over-temperature; Under/Over voltage.Identify and correct the fault (e.g., reduce load, fix short, allow cooling, check battery voltage), then restart the inverter.
Cooling fan runs constantly or loudly.High internal temperature due to heavy load or poor ventilation.Reduce load; Improve ventilation around the inverter.

8. Fa'amatalaga

The following table outlines the technical specifications for the Cotek SP-3000 Series Pure Sine Wave Inverter, specifically for the SP-3000-112 model.

Detailed specifications table for Cotek SP-3000 series inverters
Ata 5: Technical specifications for the Cotek SP-3000 Series, including the SP-3000-112 model.
VaegaParameterSP-3000-112
Tuuina atuAC Voltage100 / 110 / 115 / 120VAC ±5%
Malosi Faatatau3000W
Surge Power (1 Sec.)6000W
Malosi maualuga e maua mai ai (1 min)3450W
Galulue Fa'atinoGalu Sine Mama (THD<3%)
Fa'atele50 / 60 Hz ±0.5%
UlufaleDC Voltage12VDC
Voltagu lautele10.5 ~ 16.5VDC
Leai se uta i le taimi nei<3.0A@12VDC
Faiga Fa'asao Malosi<0.4A@12VDC
Lelei (Max.)90%
PuipuigaInput Under - Voltagu Puipuiga10.5 ±0.3VDC
Input Under - Voltagu atuatuvale11.0 ±0.3VDC
Input Under - Voltagu Toe Faʻaleleia12.0 ±0.3VDC
Input Over - Voltagu Puipuiga16.5 ±0.3VDC
Input Over - Voltagu Toe Faʻaleleia14.5 ±0.3VDC
Ova le AvegaTapuni galuega faatino voltagu, toe amata e toe faʻaleleia
Puupuu GaluegaTapuni galuega faatino voltagu, toe amata e toe faʻaleleia
SiosiomagaGalulue Temp.-20°C ~ +40°C
Temp. & Susū-30°C ~ +70°C, 10 ~ 95% RH
lauteleFua (W x H x D)442 x 214 x 102 mm (17.4 x 8.4 x 4.0 inisi)
mamafa8.2kg (18.1 lbs)
Fa'aliliSu'e malūlū e pulea le vevela & uta
Mechanical drawings with dimensions for Cotek SP-3000 series inverter
Ata 6: Mechanical drawings providing dimensional information for installation planning.

9. Fa'amaonia ma Lagolago

9.1 Fa'amatalaga Fa'amaonia

The Cotek SP-3000-112 Pure Sine Wave Inverter comes with a 2-Tausaga Fa'amaumauga Fa'atonu. O lenei tusi saisai e aofia ai fa'aletonu i meafaitino ma galuega i lalo ole fa'aoga masani. Fa'amolemole taofi lau fa'amaoniga o le fa'atau mo tagi fa'amaonia.

9.2 Fesoasoani mo Tagata Fa'atau

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cotek customer support through their official website or your point of purchase. Provide your model number (SP-3000-112) and a detailed description of the issue to expedite service.

Pepa Fa'atatau - SP-3000-112

Preview COTEK SP Series Pure Sine Wave Inverter Manual's User's Manual
Ta'iala fa'aoga mo le COTEK SP Series Pure Sine Wave Inverters (SP-700 i le SP-4000). A'oa'o e uiga i le fa'apipi'iina, fa'agaioiga, saogalemu, fa'amatalaga fa'atekinisi, ma mea fa'apitoa e pei o le galu mama mama ma le puipuiga malosi.
Preview COTEK SP Series Pure Sine Wave Inverter Manual's User's Manual
Comprehensive user's manual for COTEK SP Series Pure Sine Wave Inverters (SP-700, SP-1000, SP-1500, SP-2000, SP-3000, SP-4000). Covers specifications, installation, operation, safety, and RS-232 communication for reliable power conversion.
Preview COTEK SPT Series Pure Sine Wave Inverter with Transfer Switch - Fa'atomuaga o Mea ma Fa'amatalaga
O se mea puupuuview o le COTEK SPT Series Pure Sine Wave Inverters with Transfer Switch, faʻamatalaina a latou faʻamatalaga faʻapitoa, foliga o oloa, taʻiala faʻapipiʻi, ma faʻamatalaga faʻamaonia mo faʻataʻitaʻiga eseese.
Preview COTEK SE Series Pure Sine Wave Inverter User Manual (200W, 350W, 400W)
Comprehensive user manual for the COTEK SE Series Pure Sine Wave Inverters, covering models 200W, 350W, and 400W. This guide provides detailed information on safety precautions, product features, electrical specifications, installation procedures, operation, maintenance, troubleshooting, and warranty details.
Preview COTEK SK Series 1500W Pure Sine Wave Inverter User's Manual
Comprehensive user's manual for the COTEK SK Series 1500W Pure Sine Wave Inverter, covering safety, features, specifications, installation, operation, maintenance, and troubleshooting. Provides detailed guidance for proper use and care.
Preview COTEK SK120, SK200, SK350 Fa'asologa Fa'asologa Fa'aliliuina Galue Sina Mama Tusitaiala Fa'aoga
O lenei tusi lesona o loʻo tuʻuina atu ai faʻamatalaga auʻiliʻili ile COTEK SK120, SK200, ma le SK350 faʻasologa faʻaliliuga mama mama, e ufiufi ai le saogalemu, foliga, faʻapipiʻiina, faʻagaioiga, faʻafitauli, ma le faʻamaonia.