1. Folasaga
This manual provides essential information for the proper installation, operation, and maintenance of the Laupapa Pulea o le Ogaumu Suiga a le Carrier HK42FZ014 OEM. This control board is a critical component designed to manage the various functions of your furnace, including ignition, blower operation, and safety protocols. Adherence to these instructions is crucial for safe and efficient operation.
The HK42FZ014 is an original equipment manufacturer (OEM) replacement part, ensuring compatibility and performance with specified Carrier furnace models.
2. Fa'amatalaga Saogalemu
LAPATAIGA: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- motusia le Malosi: Always disconnect all electrical power to the furnace before installing or servicing the control board. Failure to do so can result in electrical shock, personal injury, or death.
- Fa'atonuga ole Eletise (ESD) Lapataiga: Electronic components are sensitive to static electricity. AVOID ELECTROSTATIC DISCHARGE by touching a grounded metal object (such as the furnace chassis) before handling the control board. Use an ESD wrist strap if available.
- Fa'amaonia Uea: Ensure all wiring connections are correct and secure according to the furnace manufacturer's specifications and wiring diagrams.
- Fautuaina Fa'atonu Fa'apitoa: Due to the complexity and safety implications, installation by a certified HVAC technician is strongly recommended.
3. Control Board Components Overview
The Carrier HK42FZ014 control board integrates various circuits and terminals to manage furnace operations. Familiarize yourself with the key areas:

Ata 3.1: Carrier HK42FZ014 Furnace Control Board. This image displays the full circuit board with various components, relays, and terminal blocks visible.
- Terminal Blocks (Y1, DHUM, G, Com, W, Y/Y2, 24V): These screw terminals are for connecting low-voltage thermostat wires and other control signals. "Com" typically refers to the common wire, and "24V" is the 24-volt power supply.
- Fuse: The board includes fuses (e.g., 3-AMP) to protect the circuitry from overcurrent. Always replace with a fuse of the same rating.
- Relays (A, O, M): These larger black components are relays that switch higher voltage circuits for components like the blower motor, igniter, and gas valve. The labels "A", "O", and "M" correspond to specific functions.
- Status Code LED: A small LED indicator provides diagnostic fault codes. Refer to the furnace service manual for specific flash codes.
- Connectors (EAC-1, EAC-2, SEC-1, SEC-2): Various plug-in connectors for accessories or specific furnace components.
- "COOL HEAT" Indicators: These labels near the relays indicate connections for cooling and heating functions.
- "BLOWER OFF-RELAY": This label indicates the relay responsible for controlling the blower motor's off cycle.
4. Fa'atonu Fa'atonu
Follow these general steps for replacing the furnace control board. Always refer to your specific furnace model's service manual for detailed wiring diagrams and procedures.
- Malosi motusia: Turn off all electrical power to the furnace at the main service panel. Verify power is off using a voltage su'e.
- Komiti Pulea Avanoa: Open the furnace access panel to locate the existing control board.
- Uaea pepa: Before disconnecting any wires, take clear photos or draw a detailed diagram of all connections to the old board. Label each wire carefully.
- motusia uaea: Carefully disconnect all wires from the old control board.
- Aveese le Papa Tuai: Unmount the old control board from the furnace chassis. Note how it was secured.
- Fa'apipi'i Fono Fou: Mount the new HK42FZ014 control board in the same location and orientation as the old one. Ensure it is securely fastened.
- Feso'ota'i Uaea: Reconnect all wires to the new board, matching them precisely to your documented diagram. Double-check every connection for tightness and correctness. Pay attention to the "Y1 DHUM G Com W Y/Y2" terminals for thermostat wiring and "COOL HEAT" connections for relays.
- Verify Fuses: Ensure the fuses (e.g., 3-AMP) are correctly seated and are of the appropriate rating.
- Tapuni Avanoa Laulau: Once all connections are verified, close the furnace access panel.
- Faʻafoʻi Mana: Restore electrical power to the furnace at the main service panel.
- Fa'atino Su'ega: Initiate a heating or cooling cycle to verify proper furnace operation. Observe the "STATUS CODE LED" for any diagnostic indications.
5. Galuega
The HK42FZ014 control board operates automatically, responding to signals from the thermostat and internal furnace sensors to manage the heating and cooling cycles. Key operational aspects include:
- Fa'asologa fa'amumu: Controls the sequence for igniting the burner, including pre-purge, igniter activation, gas valve opening, and flame sensing.
- Blower Control: Manages the operation of the indoor blower motor for both heating and cooling cycles, as well as continuous fan operation if selected at the thermostat. The "BLOWER OFF-RELAY" helps manage this function.
- Mata'ituina o le Saogalemu: Continuously monitors various safety devices (e.g., limit switches, flame sensor) and will shut down the furnace if a fault is detected, displaying a diagnostic code via the "STATUS CODE LED".
- LED su'esu'e: The "STATUS CODE LED" provides visual feedback on the board's status and any detected faults. Consult your furnace's service manual for a list of LED flash codes and their meanings.
6. Tausiga
The HK42FZ014 control board itself requires minimal maintenance. However, periodic inspection of the furnace system is recommended to ensure optimal performance and longevity of all components, including the control board.
- Asiasiga Faaletausaga: Have a qualified HVAC technician perform an annual inspection of your furnace. They can check electrical connections, clean components, and verify proper operation of the control board and associated safety devices.
- Mama: Ensure the area around the control board is free from dust and debris, which can interfere with electronic components.
- Uea Amiotonu: Periodically check for any loose or corroded wiring connections to the control board. (Ensure power is disconnected before inspection).
7. Faʻafitauli
If your furnace is not operating correctly after control board installation, or if issues arise, the "STATUS CODE LED" on the HK42FZ014 board is your primary diagnostic tool. Always disconnect power before inspecting or attempting repairs.
- No Power to Furnace:
- Check the main circuit breaker for the furnace.
- Verify the furnace disconnect switch is in the "ON" position.
- Inspect the fuses on the control board (e.g., 3-AMP fuse) for continuity.
- Furnace Not Heating/Cooling:
- Check thermostat settings and ensure it's calling for heat or cool.
- Observe the "STATUS CODE LED" for diagnostic flashes. Refer to your furnace manual for code interpretations.
- Verify all low-voltage thermostat wires are securely connected to the "Y1 DHUM G Com W Y/Y2" terminals.
- E le o galue le masini ea e feula ai:
- Check if the thermostat fan setting is "ON" or "AUTO".
- Listen for the "BLOWER OFF-RELAY" clicking.
- Consult LED codes for blower-related faults.
- Fa'agaoioiga fa'alavelave:
- Loose wiring connections can cause intermittent issues. Re-check all connections.
- Ensure proper grounding to prevent electrostatic interference.
If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for further diagnosis and repair.
8. Fa'amatalaga
| Fa'aaliga | Fa'amatalaga |
|---|---|
| Numera Fa'ata'ita'i | HK42FZ014 |
| Tufuga | Va'ava'a |
| Ituaiga Oloa | OEM Replacement Furnace Control Board |
| Fua | 6 x 6 x 6 inisi |
| mamafa | 13.72 aunese |
| ASIN | B00FPP02EY |
| Aso Muamua Maua | Oketopa 8, 2013 |
9. Fa'amatalaga Fa'amaonia
As an OEM replacement part, the Carrier HK42FZ014 Furnace Control Board is typically covered by the manufacturer's standard warranty for replacement parts. Warranty terms and duration may vary. Please refer to the official Carrier warranty documentation provided with your original furnace or contact Carrier customer service for specific details regarding this replacement part.
Retain your proof of purchase for any warranty claims.
10. Lagolago Fa'atekinisi
For technical assistance, complex troubleshooting, or professional installation, it is recommended to contact a qualified and certified HVAC technician. They possess the necessary expertise and tools to safely diagnose and resolve issues related to furnace control boards and overall HVAC system operation.
You may also refer to the official Carrier website or contact their customer support for product-specific inquiries.