Fluke Networks LRAT2-CIQ-GSV

Fluke Networks LRAT2-CIQ-GSV LinkRunner AT 2000/CableIQ Gigabit Service Kit

Tusi Taiala

1. Folasaga

The Fluke Networks LRAT2-CIQ-GSV LinkRunner AT 2000/CableIQ Gigabit Service Kit is a comprehensive solution designed for network technicians to analyze and test Ethernet networks over both copper and fiber optic cable infrastructures. This kit provides the necessary tools to quickly identify and troubleshoot network problems, assess cabling bandwidth, and verify network service availability.

O agava'a autu e aofia ai:

  • Portable troubleshooting for Ethernet networks.
  • Automated connectivity tests to diagnose network issues.
  • Analysis of copper and fiber cabling, including 10M/100M/1G connections and Power over Ethernet (PoE) performance.
  • Discovery of VLAN ports and switches to pinpoint potential problems.
  • Measurement of DHCP and DNS service availability and responsiveness.
  • CableIQ qualification for voice, 10/100/1000 Ethernet, VoIP, or CATV on various copper cabling types.
  • IntelliTone Pro 200 probe for tracing and isolating copper cabling.

2. Mea i totonu o le afifi

Upon opening your Fluke Networks LRAT2-CIQ-GSV kit, verify that all components are present and in good condition. The kit includes the following items:

Fluke Networks LRAT2-CIQ-GSV LinkRunner AT 2000/CableIQ Gigabit Service Kit components laid out

Image: The complete Fluke Networks LRAT2-CIQ-GSV kit, showcasing the LinkRunner AT 2000, CableIQ tester, IntelliTone Pro 200 probe, various cable adapters, power supply, USB cables, Ethernet cables, CD, and carrying cases.

  • LinkRunner AT 2000 Network Auto-Tester
  • CableIQ Qualification Tester
  • IntelliTone Pro 200 Probe
  • Remote ID units (various types)
  • Power adapters and international plugs
  • Uaea USB
  • Ethernet patch cables
  • Coax cables
  • RJ11/RJ45 adapters
  • CD software
  • Carrying cases for LinkRunner AT and CableIQ
  • Fa'amaumauga a tagata fa'aoga

3. Seti

  1. Tatala Vaega: Carefully remove all items from the packaging and inspect them for any signs of damage.
  2. Totogi ma'a: Before first use, ensure both the LinkRunner AT 2000 and CableIQ are fully charged. Connect the provided power adapter to the device and a power outlet. The charging indicator will show the status.
  3. Malosiaga: Press and hold the power button on each device until the display illuminates.
  4. Fa'atonuga Muamua: Follow the on-screen prompts for initial setup, which may include language selection, date, and time settings.
  5. Fa'apipi'i Polokalama (Filifili): If you plan to use the included software for reporting or advanced analysis, install it on your computer using the provided CD or by downloading the latest version from the Fluke Networks webnofoaga.

4. Fa'atonuga o Galuega

O lenei vaega o loʻo tuʻuina atu ai se faʻamatalaga lauteleview of operating the LinkRunner AT 2000 and CableIQ. For detailed instructions on specific tests and advanced features, refer to the comprehensive user manual PDF available online.

4.1. LinkRunner AT 2000 Basic Operation

  1. Feso'ota'i ile Network: Plug an Ethernet cable from the network port you wish to test into the LinkRunner AT's main port.
  2. AutoTest: The LinkRunner AT will automatically perform a series of tests, including link status, duplex, speed, PoE, DHCP, DNS, and gateway connectivity.
  3. View I'uga: The display will show a summary of the test results. Navigate through the screens using the directional buttons to view detailed information for each test.
  4. Su'ega Uaea: Use the cable test function to verify cable integrity, length, and wiring. Connect a remote ID unit to the far end of the cable for comprehensive testing.

4.2. CableIQ Basic Operation

  1. Filifili le Ituaiga o Su'ega: Power on the CableIQ and select the desired test type (e.g., Discover, Qualify, Troubleshoot).
  2. Feso'ota'i Uaea: Connect the cable to be tested to the CableIQ's port. For qualification tests, connect a remote ID unit to the far end.
  3. Fa'atino Su'ega: Initiate the test. The CableIQ will analyze the cable's performance and determine if it can support specific network speeds (e.g., 100BASE-TX, 1000BASE-T).
  4. Fa'amatala I'uga: The display will show the qualification result (Pass/Fail) and provide details on any detected issues such as opens, shorts, or split pairs.

For more in-depth operational details, please refer to the official user manual: Fluke Networks LRAT2-CIQ-GSV User Manual (PDF)

5. Tausiga

  • Fa'amamaina: Fa'aaogā se mea vaivai, oamp cloth to clean the exterior of the devices. Do not use abrasive cleaners or solvents. Ensure ports are free of dust and debris.
  • Tausiga maa: To maximize battery life, avoid fully discharging the batteries frequently. Store the devices with a partial charge if they will not be used for extended periods.
  • Teuina: Store the kit in its original carrying cases in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Faʻalauiloa Firmware: Periodically check the Fluke Networks web'upega tafaʻilagi mo faʻafouga o firmware e faʻamautinoa ai le faʻatinoga sili ona lelei ma le avanoa i foliga fou.

6. Faʻafitauli

This section addresses common issues you might encounter. For more complex problems, consult the full user manual or contact Fluke Networks support.

Fa'afitauliMafuaaga e ono tupuFofo
E le ola le masini.Low or depleted battery; power button not pressed correctly.Charge the device for at least 30 minutes. Ensure the power button is pressed firmly for a few seconds.
Network test fails or shows unexpected results.Incorrect cable connection; network issue (e.g., port disabled, DHCP server down); device settings.Verify cable connections. Check network infrastructure. Reset device to factory defaults if necessary.
Cable test shows errors (e.g., Open, Short).Damaged cable; incorrect termination; faulty remote ID unit.Inspect the cable for physical damage. Re-terminate connectors. Try a different remote ID unit.

7. Fa'amatalaga

Fa'aaligaFa'amatalaga
Numera Fa'ata'ita'iLRAT2-CIQ-GSV
Fua o Mea16.38 x 15.25 x 15.13 inisi
mamafa0.04 ounces (Note: This weight seems unusually low for the kit and may refer to a single component or be an error in source data. Refer to official product documentation for accurate weight.)
TufugaFluke Networks
Muamua Aso AvanoaMati 3, 2007

8. Lagolago ma Tuutuuga

For technical support, warranty information, or to purchase accessories, please visit the official Fluke Networks web'upega tafaʻilagi poʻo la latou faleoloa Amazon.

Fa'amolemole taofi lau fa'amaoniga o le fa'atau mo tagi fa'amaonia.

Pepa Fa'atatau - LRAT2-CIQ-GSV

Preview Fluke Networks CableIQ Qualification Tester User Manual
Comprehensive user manual for the Fluke Networks CableIQ Qualification Tester, detailing features, setup, operation, troubleshooting, and specifications for network cable testing.
Preview Tusitaiala mo le Tagata Fa'aoga o le LinkRunner AT 1000/2000 Network Auto-Tester
Tusitaiala mo le Fluke Networks LinkRunner AT 1000 ma le 2000 Network Auto-Testers, e aofia ai ona vaega, setiina, fa'ata'ita'iga, tausiga, ma fa'amatalaga auiliili.
Preview Fluke Networks MicroScanner Series Cable Verifiers User Manual - Network Testing Guide
Comprehensive user manual for Fluke Networks MicroScanner Series Cable Verifiers (MicroScanner², MicroScanner PoE). Covers features, twisted pair/coaxial testing, PoE detection, toning, specifications, and troubleshooting.
Preview Taiala Vave mo le Su'ega o le Uaea+Network a le LinkIQ™/LinkIQ™ Duo
O se taʻiala puʻupuʻu mo le Fluke Networks LinkIQ™/LinkIQ™ Duo Cable+Network Tester, e aofia ai suʻega faʻavae o fesoʻotaʻiga, PoE/Ping, IntelliTone™, ma le auʻiliʻiliga o le Wi-Fi.
Preview Tusitaiala mo le Tagata Fa'aoga mo le Fa'amaoniga o le Uaea Fluke Networks MicroScanner2
O le tusi lesona mo le Fluke Networks MicroScanner2 Cable Verifier, o loʻo tuʻuina atu ai faʻamatalaga e uiga i ona foliga, faʻagaioiga, puipuiga mo le saogalemu, ma le faʻaleleia atili o le faʻafitauli.
Preview Taiala mo Tagata Fa'aoga o le Fluke Networks PRO3000 Toner ma le Probe
Taiala fa'aoga mo le Fluke Networks PRO3000 Toner ma Probe, o lo'o tu'uina atu ai fa'atonuga i le su'eina o uaea, fa'ailoaina o paga, siakiina o le polarity, su'ega o le fa'aauauina, ma fa'amatalaga fa'apitoa.