Johnson Controls MR4PMUHV-12C

Johnson Controls MR4PMUHV-12C Defrost Control User Manual

1. Folasaga

The Johnson Controls MR4PMUHV-12C Defrost Control is engineered for use in refrigeration and freezer units, supporting both hot gas and electric heat defrost methods. This control unit offers flexible defrost termination options, allowing selection between time-based or temperature-based methods. It integrates essential control functions including compressor management, defrost cycle management, fan operation control, and alarm management, providing a comprehensive solution for HVAC systems.

Johnson Controls MR4PMUHV-12C Defrost Control unit with two coiled temperature sensors

Ata 1: Johnson Controls MR4PMUHV-12C Defrost Control unit and included temperature sensors. The central gray unit features a digital display and control buttons, while two coiled gray cables with metallic tips represent the temperature sensors.

2. O a mea oi totonu o le Pusa

3. Vaega Autu

4. Seti ma Fa'apipi'i

Proper installation is crucial for the safe and efficient operation of the defrost control. Always ensure power is disconnected before beginning any installation or wiring procedures.

  1. Saogalemu Muamua: Disconnect all power to the refrigeration or freezer unit before proceeding. Follow all local electrical codes and safety guidelines.
  2. Fa'amauina: Select a suitable location for mounting the control unit and, if applicable, the separate relay pack. Ensure adequate ventilation and protection from moisture. The flexible design allows for combined or separate mounting.
  3. Feso'ota'iga uaea:
    • Connect the 24VAC power supply to the designated terminals on the control unit.
    • Wire the compressor, fans, and defrost heaters to the heavy-duty relay terminals as per the wiring diagram provided with the product.
    • Connect any external alarm systems to the dedicated alarm terminals.
  4. Fa'apipi'i fa'alogo: Install the temperature sensors in the appropriate locations within the evaporator or process area as required for accurate temperature monitoring. Ensure sensor cables are routed safely and securely.
  5. Malosiaga Muamua: Once all connections are secure and verified, restore power to the unit. The control unit display should illuminate.

5. Galuega

After successful installation, the MR4PMUHV-12C is ready for configuration and operation.

  1. Faʻaali Atuview: Upon power-up, the digital display will show the current temperature. Pressing the designated button (refer to product-specific labeling) allows toggling between evaporator and process temperature readings.
  2. Setting Defrost Parameters: Access the control unit's menu (typically via dedicated buttons) to configure defrost settings. This includes:
    • Faʻavasaina Defrost: Set the frequency at which defrost cycles occur.
    • Defrost Duration: Specify the maximum time for a defrost cycle.
    • Defrost Termination Method: Choose between time-based termination (defrost ends after a set duration) or temperature-based termination (defrost ends when a specific temperature is reached).
    • Fan Delay: Configure any fan delay settings post-defrost.
  3. Fa'atonu Fa'ailoga: Configure temperature thresholds for alarms to ensure optimal operating conditions and prompt notification of deviations.
  4. Mata'ituina: Regularly check the display for current temperatures and system status.

6. Tausiga

Routine maintenance helps ensure the longevity and reliable performance of your defrost control unit.

7. Faʻafitauli

O lenei vaega o loʻo tuʻuina atu ai taʻiala mo mataupu masani. Mo fa'afitauli lavelave, fa'afeso'ota'i tagata faigaluega agava'a.

8. Fa'amatalaga

Numera Fa'ata'ita'iMR4PMUHV-12C
Fua o Mea10.5 x 5.5 x 6.5 inisi
Mea mamafa3.17 Pounds (3.2 Pounds listed elsewhere)
Fa'ailogaJohnson Pulea
Meapalasitika
Galulue Vevela32 Tikeri Fahrenheit (0°C)
TufugaJohnson Controls Inc

9. Fa'amaonia ma Lagolago

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly or refer to the official documentation included with your purchase. Keep your proof of purchase for warranty claims.

Johnson Controls Contact Information: Please visit the official Johnson Controls web'upega tafaʻilagi mo faʻamatalaga faʻafesoʻotaʻi lata mai ma punaoa lagolago.

Pepa Fa'atatau - MR4PMUHV-12C

Preview Johnson Controls A421 Series Electronic Temperature Controls with Off-Cycle Defrost Installation Instructions
Comprehensive installation guide for Johnson Controls PENN A421 Series Electronic Temperature Controls, featuring off-cycle defrost functionality. Covers product overview, applications, dimensions, mounting, wiring, setup, adjustments, troubleshooting, and technical specifications.
Preview A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures
This technical bulletin from Johnson Controls details the A419 Series Electronic Temperature Controls, designed for single-stage refrigeration and HVAC applications. It covers features, benefits, NEMA 1 and NEMA 4X enclosure options, operation, wiring, adjustments, troubleshooting, fault codes, ordering information, and technical specifications.
Preview Johnson Controls A19 Series Remote Bulb Control - Temperature Sensors
Detailed specifications and selection guide for Johnson Controls A19 Series remote bulb temperature controls, used in HVAC, heating, ventilating, and refrigeration applications. Includes model numbers, electrical ratings, and features.
Preview PENN A19 Fa'asologa Fa'amama Mamao Pulea Catalog Page | Johnson Pulea
Itulau fa'amaumauga mo le PENN A19 Series Remote Bulb Controls, fa'aalia tasi-stage pulea le vevela i elemene e tumu i le vai. E aofia ai siata filifiliga, faʻamatalaga faʻapitoa, vaega sui, ma faʻamatalaga faʻafesoʻotaʻi.
Preview Hx 3 Touch Screen Thermostat User Information Manual
O lenei tusi lesona faʻamatalaga o loʻo tuʻuina atu ai faʻamatalaga auiliili ma taʻiala mo le Johnson Controls Hx 3 Touch Screen Thermostat (Faataʻitaʻiga: S1-THXU430W), e aofia ai le faʻapipiʻiina, foliga, faʻaogaina, fesoʻotaʻiga app, ma faʻatulagaga.
Preview G600 Series Replacement Intermittent Pilot Ignition Controls Installation Instructions
Comprehensive installation, mounting, wiring, setup, operation, and troubleshooting guide for the Johnson Controls G600 Series Replacement Intermittent Pilot Ignition Controls.