Johnson Controls EP-8000-3

Johnson Controls EP-8000-3 Electro Pneumatic Transducer User Manual

Fa'ata'ita'iga: EP-8000-3 | Fa'ailoga: Johnson Pulea

1. Oloa Ua Ovaview

The Johnson Controls EP-8000-3 is an electro-pneumatic transducer designed to convert a standard electrical input signal into a proportional pneumatic output signal. Specifically, it accepts a 4-20 mA DC electrical input and produces a 3-15 PSIG pneumatic output. This device is crucial in industrial control systems for interfacing electronic controllers with pneumatic actuators or other pneumatic equipment. It features a low volume output, ensuring precise and responsive control.

Image of Johnson Controls EP-8000 series electro-pneumatic transducer, showing model EP-8000-2, a gray cylindrical device with electrical and pneumatic connections.

This image displays a Johnson Controls electro-pneumatic transducer, specifically the EP-8000-2 model, which is representative of the EP-8000 series. It is a compact, gray cylindrical unit designed for converting electrical signals to pneumatic signals. Visible features include the brand name 'JOHNSON CONTROLS', model number 'EP-8000-2', input/output specifications, and connection points at the base.

2. Fa'amatalaga Saogalemu

Read and understand all instructions before installing, operating, or maintaining this device. Failure to follow these instructions may result in property damage, personal injury, or death.

  • O le fa'apipi'iina ma le tautua e tatau ona fa'atinoina e na'o tagata faigaluega fa'apitoa.
  • Disconnect all power sources before wiring or servicing the transducer.
  • Ensure pneumatic supply lines are depressurized before making or breaking connections.
  • Verify that the operating environment is within the specified temperature and humidity ranges.
  • Do not exceed the maximum rated input current or output pressure.

3. Seti ma Fa'apipi'i

3.1 Fa'amauina

Mount the EP-8000-3 transducer in a location free from excessive vibration, moisture, and extreme temperatures. Ensure adequate space for wiring and pneumatic connections, as well as for future maintenance. The device should be mounted securely to prevent movement during operation.

3.2 So'oga Fa'aeletise

Connect the 4-20 mA DC input signal to the designated electrical terminals. Observe proper polarity. Use appropriate gauge wiring for the application and ensure all connections are secure to prevent intermittent operation or signal loss. Refer to the device's labeling for specific terminal assignments.

3.3 Feso'ota'iga Pneumatic

Connect the regulated pneumatic supply (typically 20 PSIG for a 3-15 PSIG output range) to the supply port. Connect the output pneumatic line to the designated output port. Ensure all pneumatic connections are leak-free using appropriate fittings and sealing methods. The pneumatic supply must be clean, dry, and oil-free instrument air.

4. Galuega

Once properly installed and connected, the EP-8000-3 transducer will convert the incoming 4-20 mA DC electrical signal into a proportional 3-15 PSIG pneumatic output. A 4 mA input will correspond to a 3 PSIG output, and a 20 mA input will correspond to a 15 PSIG output. The transducer operates continuously as long as power and pneumatic supply are provided.

4.1 Calibration (if applicable)

While the EP-8000-3 is factory calibrated, periodic verification of its output against a known input signal is recommended. If field calibration is required, consult the specific calibration procedure outlined in the full technical data sheet or contact Johnson Controls technical support. Typically, calibration involves adjusting zero and span settings to ensure accurate conversion across the full range.

5. Tausiga

The EP-8000-3 transducer is designed for reliable operation with minimal maintenance. However, regular inspection can help ensure optimal performance and longevity.

  • Su'ega Fa'avaitaimi: Visually inspect the transducer and its connections for any signs of damage, corrosion, or loose wiring/tubing.
  • Mama: Keep the exterior of the device clean and free from dust or debris. Do not use harsh chemicals or abrasive cleaners.
  • Pneumatic Supply Quality: Ensure the pneumatic supply remains clean, dry, and oil-free. Contaminants can affect the transducer's performance and lifespan.
  • Feso'ota'iga Amiotonu: Periodically check electrical and pneumatic connections for tightness.

6. Faʻafitauli

If the EP-8000-3 transducer is not functioning as expected, consider the following troubleshooting steps:

Fa'ailogaMafuaaga e ono tupuGaioiga
No pneumatic outputNo electrical input signal; No pneumatic supply; Faulty wiring/tubing; Device failureVerify 4-20 mA input; Check pneumatic supply pressure; Inspect connections; Replace device if necessary
Incorrect pneumatic outputIncorrect input signal; Calibration drift; Incorrect pneumatic supply pressureVerify 4-20 mA input signal accuracy; Check pneumatic supply pressure; Perform calibration if required
Unstable pneumatic outputFluctuating input signal; Unstable pneumatic supply; Loose connections; VibrationCheck stability of input signal and pneumatic supply; Secure all connections; Reduce vibration if possible

If troubleshooting steps do not resolve the issue, contact Johnson Controls technical support for further assistance.

7. Fa'amatalaga

  • Fa'ata'ita'iga: EP-8000-3
  • Tufuga: PULE JOHNSON
  • Faailoga o Faʻamaumauga: 4-20 mA DC
  • Fa'ailoga Fa'ailoga: 3-15 PSIG
  • Ituaiga Fa'atino: Leo maualalo
  • Ituaiga oloa: Electro Pneumatic Transducer
  • ASIN: B005KWHVMS
  • Aso Muamua Maua: Novema 8, 2019

8. Fa'amaonia ma Lagolago

Specific warranty terms and conditions for the Johnson Controls EP-8000-3 transducer are not detailed within this manual. For information regarding product warranty, technical support, or service, please refer to the official Johnson Controls website or contact your authorized Johnson Controls distributor or sales representative. Ensure you have the product model number (EP-8000-3) and purchase details available when seeking support.

Pepa Fa'atatau - EP-8000-3

Preview Johnson Controls EP-8000 Series Electro-Pneumatic Transducers: Technical Specifications, Installation, and Operation
Detailed technical bulletin for Johnson Controls EP-8000 Series Electro-Pneumatic Transducers. Covers product overview, operation, dimensions, installation, wiring, calibration, and technical specifications for industrial control applications.
Preview Johnson Controls AD-XXX Series PureFlow Duplex Air Compressors | Product Bulletin
Comprehensive product bulletin detailing the Johnson Controls AD-XXX Series PureFlow Duplex Air Compressors, ranging from 1/2 to 20 hp. Includes features, technical specifications, performance data, ordering information, dimensions, wiring diagrams, and a complete list of repair parts.
Preview Hx 3 Touch Screen Thermostat User Information Manual
O lenei tusi lesona faʻamatalaga o loʻo tuʻuina atu ai faʻamatalaga auiliili ma taʻiala mo le Johnson Controls Hx 3 Touch Screen Thermostat (Faataʻitaʻiga: S1-THXU430W), e aofia ai le faʻapipiʻiina, foliga, faʻaogaina, fesoʻotaʻiga app, ma faʻatulagaga.
Preview Smart Equipment Controls Quick Start Guide for UCB HVAC Systems
Comprehensive quick start guide for Johnson Controls Smart Equipment Unit Control Board (UCB) HVAC systems. Learn setup, navigation, firmware updates, configuration backup, commissioning, and troubleshooting for Constant Volume, VAV, Economizer, and Heat Pump applications. Includes detailed menu structures and operational parameters.
Preview Smart Equipment™ Controls Quick Start Guide - Firmware 3.4 ma le Matua
O se ta'iala vave amata mo le Smart Equipment™ Controls (version 3.4 and old firmware), fa'amatalaga auiliili, fa'afouga fa'afouga, fa'atautaiga, ma le fa'atulagaina mo faiga fa'atonutonu HVAC.
Preview MCL Tool 5.3 Installation and Startup Guide - Johnson Controls