1. Oloa Ua Ovaview
The KING LPWV2715-CT24 is a robust, vandal-resistant electric heater designed for high-traffic and public areas such as detention facilities, public restrooms, and rest areas. Its heavy-duty construction, including a 3/16-inch solid steel frame and grill, provides exceptional durability against impact and abuse. Tamper-resistant screws secure the grill, and controls are recessed to prevent unauthorized access. This unit offers moderate wattage and high airflow to effectively heat entryways and hallways, preventing drafts from affecting the building's core temperature.

Ata 1: Luma view of the KING LPWV2715-CT24 Vandal Resistant Heater, showcasing its robust metal casing and grill.
Vaega Autu:
- Impact/Vandal Resistant: Constructed with a heavy grill and 3/16-inch solid steel frame.
- Pic-A-Watt Elements: Allows for multiple wattage options to suit specific heating requirements.
- Tamper Resistant 3 Position Switch: Offers Fan, Heat, and Off settings, designed to prevent unauthorized adjustments.
- Puipuiga ole vevela: Integrated safety feature to prevent overheating.
2. Fa'amatalaga Saogalemu
Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.
- Fa'apipi'i Eletise: This heater operates on 277 Volts and requires hardwiring. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Fa'avae: This heater must be properly grounded to reduce the risk of electric shock.
- Nofoaga: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used. Maintain proper clearances from combustible materials as specified in the installation section.
- Puipuiga ole vevela: The heater is equipped with a thermal cut-out to prevent overheating. If the heater shuts off due to overheating, allow it to cool down before attempting to restart. Investigate and correct the cause of overheating.
- Aua le Ufiufi: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
- Tausiga: Ta'e le paoa a'o le'i faia se tausiga po'o le fa'amamāina.
3. Mea i totonu o le afifi
Fa'amautinoa o lo'o iai uma vaega ma e le'i fa'aleagaina pe a tatala le afifi:
- KING LPWV2715-CT24 Vandal Resistant Heater Unit
- Mounting Hardware (typically included)
- Tusi Faʻatonuga (lenei pepa)
Afai e misi pe faaleagaina ni mea, faafesootaʻi loa lau kamupani sapalai.
4. Fa'apipi'i
LAPATAIGA: Installation must be performed by a qualified electrician. Disconnect all power to the circuit at the main service panel before attempting any wiring.
4.1 Faʻaputuga Nofoaga
- This heater is designed for indoor, wall-mount installation.
- Choose a location that allows for proper air circulation and maintains required clearances from walls, ceilings, and floors. Refer to local codes for specific clearance requirements.
- Ensure the mounting surface is structurally sound to support the heater's weight (approximately 36 pounds).
4.2 So'oga Fa'aeletise
- The LPWV2715-CT24 heater requires a dedicated 277 Volt, 60 Hz, single-phase circuit.
- O le fa'avevela e toso le 5.4 Amps at 277V, providing 1500 Watts of heat. Ensure the circuit breaker and wiring are appropriately sized for this load.
- Connect the heater directly to the electrical supply using appropriate hardwiring methods and connectors, following the wiring diagram provided inside the heater's access panel.
- Ia mautinoa o so'oga uma e mau ma malupuipuia.
5. Galuega
Once properly installed and powered, the heater can be operated using its tamper-resistant 3-position switch.
5.1 Fa'asagaga Suiga Malosi
- ESE: The heater is completely off, and no heat or fan operation will occur.
- FAN: The fan operates continuously without engaging the heating elements. This can be used for air circulation.
- VAVE: The heating elements and fan operate to provide warmth. The heater will cycle on and off to maintain the desired temperature if connected to an external thermostat (not included).
5.2 Wattage Selection (Pic-A-Watt)
The LPWV series heaters feature Pic-A-Watt elements, allowing for field-adjustable wattage settings. Refer to the wiring diagram inside the heater for instructions on how to adjust the wattage to suit specific room requirements. This adjustment should only be performed by a qualified technician with power disconnected.
6. Tausiga
Regular maintenance ensures optimal performance and longevity of your heater. Always disconnect power at the circuit breaker before performing any maintenance.
- Fa'amamaina: Fa'amama i lea taimi ma lea taimi le pito i fafo o le fa'avevela i se malu, oamp ie. Aua ne'i fa'aogaina ni mea fa'amama fa'afefete po'o ni solu.
- Ulufale/Pusa Fa'aola o le Ea: Ensure that the air inlets and outlets are free from dust, lint, and other obstructions. Use a vacuum cleaner with a brush attachment to gently clean the grill and internal components if accessible.
- Asiasiga: Annually inspect the heater for any signs of damage, loose wiring, or unusual wear. If any issues are found, contact a qualified electrician for repair.
7. Faʻafitauli
A'o le'i fa'afeso'ota'i le lagolago a tagata fa'atau, toeview mataupu masani nei ma fofo:
| Fa'afitauli | Mafuaaga e ono tupu | Fofo |
|---|---|---|
| E le kilia le fa'avevela. | Leai se eletise; Ta'atia le va'a; Uaea tatala. | Check circuit breaker; Ensure power switch is in 'HEAT' or 'FAN' position; Consult a qualified electrician to check wiring. |
| E lē gaosia e le masini fa'avevela le vevela, ae e ola le ili. | Switch in 'FAN' position; Heating elements failed; Overheat protection activated. | Set switch to 'HEAT'; Allow heater to cool if overheat protection tripped; Contact a qualified electrician for element inspection. |
| E fa'aola ma tape soo le fa'avevela. | Improper thermostat setting (if applicable); Restricted airflow; Overheat protection cycling. | Adjust thermostat setting; Clear any obstructions from air inlets/outlets; Ensure proper clearances. |
| Pisa po'o manogi e le masani ai. | Loose components; Dust accumulation on elements; Motor issue. | Disconnect power immediately; Inspect for loose parts; Clean heater; Contact a qualified electrician for inspection. |
Afai e faaauau pea le faafitauli pe a uma ona e taumafai i nei fofo, faafesootai le auaunaga a tagata faatau po o se tagata eletise agavaa.
8. Fa'amatalaga
| Fa'amatalaga | Fa'amatalaga |
|---|---|
| Fa'ailoga | TUPU |
| Numera Fa'ata'ita'i | LPWV2715-CT24 |
| Voltage | 277 Volts |
| Ampmatua | 5.4 Amps |
| Uatage | 1500 Watts |
| Fua o Mea (D x W x H) | 4"D x 13.75"W x 22.75"L |
| Mea mamafa | 36 pauna |
| Ituaiga Fa'amau | Mauga puipui |
| Ituaiga Suauu | Eletise |
| Fa'aoga i totonu/I fafo | I totonu |
| Fa'apitoa Fa'apitoa | Puipuiga ole vevela |
| UPC | 093319183731 |
| ASIN | B0G3SWW2XK |
9. Fa'amaonia ma Lagolago
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official KING webnofoaga. Taofi lau lisiti fa'atau e fai ma fa'amaoniga o le fa'atauga mo tagi fa'amaonia.
Tufuga: KING Electrical Manufacturing
Webnofoaga: www.king-electric.com (Esoample so'oga, fa'amolemole fa'amaonia aloaia webnofoaga)