1. Folasaga
Thank you for choosing the CURECURE FDP29-2025V1R3 Portable Air Conditioner. This 3-in-1 unit provides powerful cooling, efficient dehumidification, and effective fan functions, designed for comfort in various indoor environments such as living rooms, bedrooms, small rooms, studies, and offices.
With a 10,000 BTU cooling capacity, it quickly cools rooms up to 250 sq.ft. Key features include an adjustable air flow direction (130° up/down manual swing), a humanized sleep mode for quiet operation (as low as 56 dB), a 24-hour timer, a smart LED touch panel, and a remote control. For safety, a child lock feature is integrated. The unit also includes a drain plug and hose for easy water removal, and a window kit for simple installation in vertical or horizontal sliding windows (24.4"-48").

Image 1: The CURECURE Portable Air Conditioner in a modern living room setting, demonstrating its compact design and cooling capability.
2. Fa'amatalaga Taua mo le Saogalemu
Fa'amolemole faitau fa'atonuga uma ma le fa'aeteete a'o le'i fa'aogaina lenei masini. Taofi le tusi lesona lenei mo fa'amatalaga i le lumana'i.
- Ia mautinoa o le sapalai eletise e fetaui ma le voltagu fa'amaoti i luga o le fa'ailoga o le iunite.
- Aua le faagaoioia le iunite i se uaea po o se palaka ua faaleagaina.
- Aveese i taimi uma le iunite a'o le'i fa'amamāina po'o le tautua.
- Do not block air inlets or outlets. Maintain at least 30 cm (12 inches) clearance from walls and other objects.
- Do not use the unit in wet areas such as bathrooms or laundries.
- Keep children away from the appliance. The child lock feature helps prevent accidental changes to settings.
- Dispose of the unit properly in accordance with federal and local regulations for flammable refrigerants.
3. Mea i totonu o le afifi
Fa'amaonia o mea uma o lo'o lisiina i lalo o lo'o aofia i lau afifi:
- 1 x CURECURE Portable Air Conditioner Unit
- 1 x Air Exhaust Duct
- 1 x Connector of Air Exhaust Duct
- 1 x Window Exhaust Adapter
- 1 x Remote Control (with 1 Lithium Metal battery included)
- 1 x Baffle Plate (Window Kit)
- 1 x Paipa Fa'amamago
- Tusi Faʻatonuga (lenei pepa)

Image 2: Visual representation of the portable air conditioner unit, exhaust hose, drainage hose, remote control, hose connector, and window kit components.
4. Seti Taiala
Mulimuli i laasaga nei e seti ai lau ea malulu feaveaʻi:
- Fa'atulagaina o le Vaega: Place the air conditioner on a flat, stable surface near a window and a power outlet. Ensure there is at least 30 cm (12 inches) of space around the unit for proper airflow. The unit features four rolling casters for easy movement.
- Fa'apipi'iina o le Paipa Paipa Ausa: Connect the air exhaust duct to the connector, then attach the connector to the exhaust outlet on the back of the air conditioner unit. Ensure a secure fit to prevent air leakage.
- Fa'apipi'i Pusa Fa'amalama: The included baffle plate (window kit) is designed for vertical or horizontal sliding windows with a size range of 24.4" to 48". Adjust the baffle plate to fit your window opening. Insert the window exhaust adapter into the opening of the baffle plate.
- Connecting to Window: Extend the air exhaust duct and connect it to the window exhaust adapter. Ensure the hose is relatively straight to avoid blocking airflow, which can lead to overheating. Close the window securely against the baffle plate to seal the opening.
- So'oga Malosi: Plug the unit into a standard 115 Volt electrical outlet.

Image 3: Illustration of how to install the exhaust hose into the portable air conditioner and secure the window kit in both vertical and horizontal sliding windows.
5. Fa'atonuga o Galuega
Your CURECURE Portable Air Conditioner can be operated using the smart LED touch panel on the unit or the included remote control.
5.1 Pulea le Panelview

Ata 4: Auiliiliga view of the LED touch control panel, showing buttons for Sleep Mode, Child Lock, Timer, Modes, Speed, Power, and Swing.
- Ki Malosi: Liliu le iunite ON pe PI.
- Faiga Fa'amau: Ta'amilomilo e ala ile fa'aalili, Dehumidifier, ma faiga fa'ape.
- Fetuunaiga o le vevela (+/-): Increases or decreases the desired temperature. Press '+' and '-' simultaneously to switch between Fahrenheit and Celsius.
- Ki o le Saosaoa: Fetuuna'i le saoasaoa o le ili (Maualuga/Maulalo).
- Ki o le Taimi: Sets the 24-hour timer for automatic ON/OFF.
- Moe moe: Activates sleep mode, where the temperature gradually increases by 1.8°F/1°C per hour for comfortable sleep and energy saving.
- Loka Tamaiti: Engages or disengages the child lock to prevent unintended changes to settings.
- Taupega: Manually adjust the air flow direction (130° up/down).
5.2 Faiga Fa'atino

Image 5: Visual explanation of the unit's versatile 3-in-1 functionality, including Automatic, Cool, Dehumidify, and Fan modes with their respective functions.
- Faiga mālūlū: Provides powerful cooling with an adjustable temperature range of 59°F-87°F (15°C-30°C).
- Faiga Fa'asūsū: Removes up to 51 pints of moisture per day, reducing humidity in the room.
- Faiga Fan: Circulates air with two-speed settings (High/Low) for ventilation without cooling.
- Faiga otometi: Selects either cooling or fan mode based on the room temperature.
5.3 Faiga moe
Activate Sleep Mode for a comfortable night's rest. In this mode, the set temperature will automatically increase by 1.8°F (1°C) per hour to prevent overcooling and save energy. The unit operates at a low noise level of 56 dB.

Image 6: A person sleeping comfortably in a bedroom with the portable air conditioner running in its quiet Sleep Mode.
6. Tausiga
O le tausiga faifaipea e fa'amautinoa ai le fa'atinoina lelei ma le umi o le ola o lau ea malulu.
6.1 Fa'amamāina o le Fa'amama o le Ea
The air filter should be cleaned regularly (at least once a month, or more frequently depending on usage and air quality) to maintain cooling efficiency and air quality.
- Aveese le ea malulu mai le paoa.
- Saili le vaega o le faamama ea (e masani lava i tua po o le itu o le iunite).
- Remove the filter by gently pulling it out.
- Fufulu le faamama i le vai mafanafana ma le fasimoli. Fufulu lelei ma tuu e mago atoa i le ea a'o le'i toe fa'apipi'iina.
- Reinsert the dry filter back into the unit and close the panel.
6.2 Alavai
The unit has a drain plug at the bottom for easy water removal, especially when operating in dehumidifier mode or before storing the unit. Connect the provided drain hose to the drain outlet and direct it to a suitable container or floor drain.
7. Faʻafitauli
Afai e te feagai ma fa'afitauli i lau ea malulu, va'ai i fa'afitauli masani nei ma fofo:
| Fa'afitauli | Mafuaaga e ono tupu | Fofo |
|---|---|---|
| E le kilia le iunite. | Leai se paoa, tatala uaea eletise, motusia le eletise. | Check power outlet, plug in the unit, reset circuit breaker. |
| E le lelei le malulu o le iunite. | Dirty air filter, blocked air intake/outlet, room too large, window kit not properly sealed. | Clean air filter, ensure clear airflow, verify room size (max 250 sq.ft), check window kit seal. |
| Pisa le iunite. | O le iunite e le i luga o se tulaga maualuga, o vaega i totonu e tetete. | Place unit on a flat, stable surface. If noise persists, contact support. |
| Lisi vai. | Drain plug not properly secured, drainage hose blocked. | Ensure drain plug is tight, check drainage hose for kinks or blockages. |
8. Fa'amatalaga
| Fa'aaliga | Fa'amatalaga |
|---|---|
| Numera Fa'ata'ita'i | FDP29-2025V1R3 |
| Malosi Fa'alili | 10000 Iunite vevela a Peretania |
| Galuega | 3-in-1 (Cooling, Dehumidifier, Fan) |
| Malosiaga faʻaitiitia | 51 pints/aso |
| Avanoa Avanoa | E oo atu i le 250 sikuea futu |
| Tulaga Pio | 56 Tesipela |
| Voltage | 115 Volts |
| Uatage | 2900 watts |
| Fua o Mea (D x W x H) | 28D x 33W x 70H Sinimita |
| mamafa | 26 kilokalama |
| Window Kit Compatibility | 24.4" - 48" (Width/Height) |
| Metotia Pulea | Mamao, Pa'i |
| Fa'apitoa Fa'apitoa | Child Lock, Fast Cooling, Remote Controlled, Sleep Mode |
9. Fa'amaonia ma Lagolago
Fa'amaonia: The product comes with NO stated warranty. Please refer to your retailer's return policy for details on returns or replacements.
Tufuga: YIYOUYI