This manual provides essential information for the safe and efficient use of your Philips Lighting ER55LD3WR LED Exit Sign. Please read these instructions carefully before installation and operation, and retain them for future reference. This product is designed for commercial lighting applications, specifically as a lighted exit sign.

Fa'amatalaga Saogalemu

  • Always disconnect power before installing or servicing the unit.
  • E tatau ona faia le faʻapipiʻiina e se eletise agavaa e tusa ai ma tulafono faʻaeletise a le atunuʻu ma le lotoifale.
  • Aua le fa'aogaina lenei oloa mo fa'amoemoega e ese mai i lona fa'amoemoe e fa'aoga.
  • Ia mautinoa o so'oga uma o lo'o malupuipuia ma fa'amama lelei.
  • Taofi mai le vai ma le susu tele.

O mea o lo'o i totonu

Fa'amautinoa o lo'o iai vaega uma a'o le'i amata fa'apipi'i:

  • Philips Lighting ER55LD3WR LED Exit Sign unit
  • Mea fa'apipi'i (fa'amau, taula)
  • Tusi Faʻatonuga (lenei pepa)

Seti ma Fa'apipi'i

The Philips Lighting ER55LD3WR LED Exit Sign is designed for wall mounting. Ensure the mounting surface is suitable to support the weight of the unit.

  1. Saunia le Nofoaga Fa'apipi'i: Disconnect power to the circuit where the exit sign will be installed.
  2. Fa'amauina:
    • Identify the desired wall mounting location.
    • Use the provided mounting hardware to securely attach the exit sign to the wall. Ensure the unit is level.
  3. Uaea:
    • Connect the building's 120V AC power supply to the corresponding wires on the exit sign. Refer to the wiring diagram inside the unit's housing for specific connections.
    • Ia mautinoa le faavae lelei.
    • Connect the internal battery (if not pre-connected). This is crucial for emergency operation.
  4. Fonotaga Mulimuli: Secure any covers or diffusers.
Philips Lighting ER55LD3WR LED Exit Sign, front view

Ata 1: Luma view of the Philips Lighting ER55LD3WR LED Exit Sign. This image shows the white housing with the red "EXIT" lettering illuminated, indicating its primary function as an emergency egress indicator.

Fa'atonuga o Galuega

Once installed and power is restored, the Philips Lighting ER55LD3WR LED Exit Sign will operate automatically.

  • Galuega masani: When AC power is present, the "EXIT" sign will be illuminated by the internal LEDs. The green indicator light on the unit will be ON, signifying operating status.
  • Fa'alavelave fa'afuase'i: In the event of an AC power failure, the unit will automatically switch to battery backup, illuminating the "EXIT" sign for a specified duration (typically 90 minutes).
  • Ki su'ega: A test button is provided on the unit to verify emergency operation. Press and hold the "Push to Test" button to simulate an AC power failure. The sign should remain illuminated, and the green indicator light will blink, indicating testing. Release the button to return to normal operation.
Philips Lighting ER55LD3WR LED Exit Sign, test button and indicator lights

Ata 2: Fa'alatalata view of the test button and indicator lights on the Philips Lighting ER55LD3WR LED Exit Sign. The green indicator shows operating status (ON for ready, Blinking for testing). The red indicator shows service alerts such as battery, charger board, transformer, or LED strip faults.

Tausiga

Regular maintenance ensures the reliability and longevity of your LED Exit Sign.

  • Su'ega Fa'alemasina: Press the "Push to Test" button for at least 30 seconds to ensure the battery backup system is functioning. The sign should remain illuminated.
  • Su'ega Fa'aletausaga: Disconnect AC power to the unit for 90 minutes to verify the battery can sustain emergency illumination for the required duration.
  • Fa'amamaina: Fa'amama le pito i fafo o le iunite i le malu, oamp ie. Aua ne'i fa'aogaina ni mea fa'amama fa'afefete po'o ni solu.
  • Suiga maa: The internal battery has a limited lifespan. If the unit fails to hold a charge or the red "Battery fault" indicator illuminates, the battery may need replacement. Contact qualified service personnel for battery replacement.

Fa'afitauli

Va'ai le laulau o lo'o i lalo mo fa'afitauli masani ma a latou fofo.

Fa'afitauliMafuaaga e ono tupuFofo
Sign does not illuminate (AC power present)No AC power; faulty wiring; LED strip faultCheck circuit breaker; verify wiring connections; contact service for LED replacement.
Sign does not illuminate during power outage (emergency mode)Battery not connected; discharged battery; faulty battery; charger board faultEnsure battery is connected; allow 24 hours for initial charge; replace battery; contact service for charger board repair.
Red Service Alert indicator is ONIndicates battery, charger board, transformer, or LED strip fault (refer to unit label)Identify specific fault from unit label; perform monthly/annual tests; contact qualified service personnel.
Green Operating Status indicator is OFF (AC power present)No AC power; internal faultCheck AC power supply; contact qualified service personnel.

Fa'amatalaga

Fa'aaligaFa'amatalaga
Numera Fa'ata'ita'iER55LD3WR
Fa'ailogaPhilips moli
Ituaiga Puna MalamalamaLED
Voltage120 Volts
Punavai MalosiUaea Eletise
Ituaiga Fa'amauMauga puipui
MeaUamea
LanuLanu pa'epa'e
Fua o Mea4.25 x 6.25 x 4.8 inisi
Mea mamafa4.98 pauna
UPC781370410117

Fa'amaonia ma Lagolago

For warranty information or technical support, please contact Philips Lighting customer service. Keep your purchase receipt as proof of purchase.

Tufuga: Philips moli

Webnofoaga: Asiasi ile Faleoloa PHILIPS ile Amazon

© 2023 Philips Lighting. Ua taofia aia tatau uma.

Pepa Fa'atatau - ER55LD3WR

Preview Philips Lighting 3-Hour Compliant Exit Sign Emergency Light LED
Information on the Philips Lighting Emergency Light LED Exit Sign, featuring 3-hour battery duration, self-test function, LFP battery technology for environmental friendliness and longevity, and suitability for various applications like airports, offices, and retail spaces.
Preview Philips Lighting 3-Hour Compliant LED Exit Sign Emergency Light
Information on the Philips Lighting Emergency Light LED Exit Sign, a 3-hour compliant emergency lighting solution with maintained mode, suitable for various applications like airports, offices, and retail. Features a long-lasting, environmentally friendly LFP lithium battery.
Preview Philips Lighting 3-Hour Compliant LED Exit Sign Emergency Light
Information on the Philips Lighting Emergency Light LED Exit Sign, featuring 3-hour battery duration, maintained mode, and welfare-friendly lithium battery technology. Suitable for airports, offices, and retail applications.
Preview Philips EM133C Emergency Razor LED Exit Sign - Product Specifications
Detailed specifications for the Philips EM133C Emergency Razor LED Exit Sign, including technical data, performance metrics, and physical dimensions. Features a 2.2W LED, 19 lm output, 7000K color temperature, and IP20 rating.
Preview Philips Lighting Stand-alone 3-Hour Compliant Exit Signs
Philips Lighting offers stand-alone, 3-hour compliant emergency exit signs (EM155C and EM159C) that meet European regulations. These signs feature lithium-based batteries for longer life and better performance, and are available with various legends and mounting options.
Preview Philips EM159Z WL/CM Exit Sign Legend Left/Right - Product Data and Specifications
Detailed product information for the Philips EM159Z WL/CM Exit Sign Legend Left/Right, including technical specifications, safety features, and compliance data. This emergency lighting solution is designed for building safety and adheres to European regulations.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.